5

2) Adjusting the gap between input table and main roll

The gap between main roll and input table can be adjusted by pins coming out from the input table. To adjust: follow the procedure on the previous page, except for bolt B1.

To move the pins forward: screw B3 until desired. To move the pins backward: unscrew B3.

Tighten bolts B2.

B2

B1

H_S

B3

T

H_S

41

5

Troubleshooting

Starting problems

Fault

 

Cause

 

 

Remedy

 

 

 

No air has been exhausted.

 

 

Clean fan.

"No air" on display

 

 

 

Clean outlet tube.

 

 

 

Fan blocked.

 

 

Eliminate the fault.

 

 

 

Vacuum valve does not connect.

 

 

Check if the valve’s switch connects.

 

 

 

 

 

 

Check position/switching point of the switch.

 

 

 

Plug of vacuum valve is not inserted.

 

Insert the plug in the right input of the control.

 

 

 

Malfunction frequency converter.

 

 

See page 44.

"No speed" on

Frequency converter out of order.

 

 

See page 44.

display

 

Plug of drive is not inserted.

 

 

Insert the plug in the right input of the control.

 

 

 

Speed sensor does not detect pulses.

 

Adjust distance chain wheel and sensor to 1mm.

 

 

 

 

 

 

Out of order, replace sensor.

 

 

 

Burner in reset.

 

 

Open gas tap and reset burner.

 

 

 

Ionization follow-upcable not inserted well in

 

Insert plug well in burner and control print.

"No heat" on

contact of burner.

 

 

 

Plug of heating is plugged out of the burner.

 

Insert plug in right input of the control.

display

 

 

 

No gas in pipe at first set-up.

 

 

Make many start attempts, with resets in the

 

 

 

 

 

 

 

 

 

 

 

meantime, so that air is removed from the pipes.

 

 

 

Overheat switch tripped.

 

 

Check system and reset switch.

 

 

 

Fuse gas control broken.

 

 

Replace fuse after controlling system.

"Foot" on display

Foot pedal is operated.

 

 

Release the foot pedal.

 

 

 

Readjust the switch.

 

 

 

 

 

 

Tighten the springs.

"Heat1" or

Temperature sensor cable interrupted.

 

Check cable and repair defects.

"Heat2" on display

Temperature sensor out of order.

 

 

Replace the sensor by a new one.

(number of the

Input on control out of order.

 

 

Replace the control by a new one.

defective sensor)

 

 

Frequency converter

 

 

 

 

 

 

 

 

 

 

Fault

 

 

Condition

 

 

Possible cause

OI.AC**

 

Drive output instantaneous over current.

Insufficient ramp times.

 

 

 

 

Phase to phase or phase to ground short circuit on the drives

 

 

 

 

output.

 

 

 

 

 

Drive requires autotuning to the motor.

 

 

 

 

Motor or motor connections changed, re-autotunedrive to motor.

It.AC

 

I²t on drive output current.

Excessive mechanical load.

 

 

 

 

High impedance phase to phase or phase to ground short circuit

 

 

 

 

at drive output.

 

 

 

 

 

Drive requires re-autotuningto motor.

HFxx trip

 

Hardware faults.

Internal drive hardware fault.

42

5

Fault

Condition

Solution

OVL.d

I x t overload (I = current, t = time).

Reduce motor current (Load).

hot

Heatsink/IGBT temperature high.

Reduce ambient temperature or reduce motor current.

br.rS

Braking resistor overload.

Call Customer Service.

AC.Lt

Drive is in current limit.

Call Customer Service.

Burner

Fault

Cause

Remedy

Continuous

No supply voltage so also no burning

Check fuses and wiring.

malfunction

reset lamp.

 

after reset

Overheat.

Check overheat thermostat (see Fig. 1).

 

Short-circuitelectrode to earth.

Adjust electrode properly ->ignition probe: 3 mm from burner

 

 

(see Fig. 2).

 

No gas supply.

Check gas supply, gas tap and function of the gas valves.

Malfunction

 

Adjust electrode properly.

burner after

No ignition spark.

2 start

 

Machine has no contact with earth.

 

Check electrical connection of the machine.

attempts

 

 

Check overheat thermostat.

 

 

 

No ignition while there is a spark.

No gas supply.

 

 

Wrong adjustment gas valve.

 

 

No PWM signal on ventilator (turns full at spark).

thermostat

3 mm

Fig. 1

Fig. 2

43

6

Description of the control system

General description of the control system

The control system consists of a microprocessor board with built-ondisplay andpush-buttons.

Electric heating control

For the electric heated version, the relays for the heating elements are controlled by a time related P.I.D. controlled function built in the program of the processor, which has the opportunity of a quick reaction with limited overshoot. The elements are activated by relays.

Gas heating

With the gas version, a PWM controlled ventilator is used, which is controlled by the microprocessor.

This ventilator blows the mix of gas and air into the burner, which means that the power of the burner is controlled by the microprocessor. The advantage is that also here the burner is controlled with a P.I.D. controlled function from 20-40to 100% so that there is a quick reacting system with a low overshoot.

When the need of power is lower than 15%, the burner will be temporarily switched off.

Temperature control

The temperature of the roll is measured by Pt1000 elements that are mounted on a contact plate on the roll. The Pt1000 are directly connected to the microprocessor board.

To prevent overheating when there is a malfunction of the Pt1000 or the microprocessor board,

a maximum temperature switch is placed, which switches off the power of the relay of the elements or the power of the gas control unit.

temp2: left sensor

temp1: right sensor

44

6

Control of exhaust ventilator

The exhaust ventilator always turns on maximum when the ironer is switched on. An underpressure switch is mounted, which controls the working of the exhaust ventilator. The function of this underpressure switch is controlled when starting up the machine and will give a warning sign when the function is not correct.

Speed control

The speed is controlled by means of a frequency regulator, which is controlled by a feedback system through the microprocessor board.

The speed is checked by an approximated switch, which is activated by the teeth of a detection wheel.

teeth of a detection wheel

approximated switch

Start/stop function

The ironer can be started and stopped by pressing the 0/I button.

The foot pedal can temporarily stop the ironer.

45

6

Control panel and function keys

The machine is equipped with the following operating devices:

1: Emergency stop button 2: Reset gas

3: Start/stop button 4: “+” Button

5: “-“Button

6: Return button

7: Left display (temperature) 8: Right display (speed)

When the power is switched to the machine by the main switch, “” and the program version will appear during 5 seconds.

Then the left display will give the actual temperature (in °C or °F) and the right display will give the actual speed (in M/min).

46

6

Menu structure and how to enter

After installation, each ironer needs to be configured.

There are 2 different systems: Manual and Coin version.

Manual version

When the main switch is switched on, "" appears on the right display during 5 seconds.

To enter the adjusting menus, press the I/0 button and ↓ button simultaneously until "" appears on the right display. With the + and - button, it is possible to switch between the menus,and

. By pressing the ↓ button, you choose a specific menu.

5 sec

I/0 +

I

- + - +

+ -

Coin version: hidden buttons

The hidden buttons (A) normally have no function in the coin version.

However, during the configuration, they have the same function as the manual version.

A

47

6

Menu structure

When the main switch is switched on, "" appears on the right display during 5 seconds.

To enter the adjusting menus, activate the microswitch inside the coin box casing.

When "" appears, keep pressing the microswitch (approximately 5 sec.) until "" appears on the display. Then press the “I” button to reset the emergency stop, after which the blinking "" menu will appear on the right display.

Then press the hidden ↓ button until 3 blinking dashes appear on the left display (approximately 2 sec.).

Release the ↓ button and press the microswitch again (approximately 5 sec.) until "" lights up on the right display.

With the + and - button, it is possible to switch between the menus

,

and

.

By pressing the ↓ button, you choose a specific menu.

5 sec

2 sec

5 sec

I

5 sec

 

- + - +

+ -

48

6

"Manu" adjusting menu

This is the group of parameters for the manual ironer with start button action.

+

+

-

+

-

+

-

+

-

+

-

+

-

Manu

Press the return button to continue.

t °C or t °F [default: °C]

Change, if necessary, by means of the + button and then press the return button.

XX Cool [default: 80°C]

This cool down temperature can be adjusted between 80 and 100°C by pressing the + or - button.

Then press the return button.

Iron

The following settings determine the 2 temperatures in between which it will be possible to set the temperature during operation.

XXX Low [default: 130°C]

This is the low limit temperature.

It can be changed by pressing the + or - button.

Then press the return button.

XXX High [default: 175°C]

This is the high limit temperature.

It can be changed by pressing the + or - button.

Then press the return button.

SP.L X.X [default: 1,4 m/min]

This is the low limit of the speed.

It can be changed by pressing the + or - button.

Then press the return button.

SP.H X.X [default: 6 m/min]

This is the high limit of the speed.

It can be changed by pressing the + or - button.

Then press the return button.

A.St X.X [default: 0.0]

In order to avoid that the ironer remains unused at temperature for a long time, it is possible to enter a switch off time.

In case of “0.0”, the cycle must be stopped manually.

Then press the return button.

X X X

End

Press the return button to confirm the setting of this parameter group.

49

6

"Coin" adjusting menu

This is the group of parameters for the coin operated ironer.

 

 

 

 

 

 

 

 

 

Coin

 

 

 

 

 

 

 

 

 

Press the return button to continue.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on t °C [default : °C]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

By selecting this parameter, the temperature will be calculated and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shown in °C. Press the return button to choose this option.

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off t °C [default : °C]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

By selecting this parameter, the temperature will be calculated in °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

but not shown during operation. Press the return button to choose this

 

 

+

+

 

 

option.

 

 

 

 

 

 

 

 

 

On t °F [default : °F]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

By selecting this parameter, the temperature will be calculated and

 

 

 

 

 

 

 

 

 

shown in °F. Press the return button to choose this option.

+

Off t °F [default : °F]

By selecting this parameter, the temperature will be calculated in °F but not shown during operation. Press the return button to choose this

option.

+

-

+

XX Cool [default : 80°C]

This cool down temperature can be adjusted between 80 and 100°C by pressing the + or - button.

Then press the return button.

-

+

-

+

XXX Iron [default : 160°C]

This is the operating temperature of the ironer. This can be adjusted between 130 and 175°C with the + and - button. Then press the return button.

SP X.X [default : 1.4 m/min]

This is the operating speed of the ironer belts. It can be changed with the + and - button.

Then press the return button.

 

 

 

 

 

 

 

C1L (coin 1 low)

 

 

 

 

 

 

 

Here, you can adjust the time in minutes and seconds with the + and -

 

 

 

 

 

-

 

 

 

 

 

button for low tariff coin 1. Then press the return button.

 

 

50