Installation

Installation must conform with local codes or, in the absence of local codes, with:

In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”

In Canada, installation must comply with StandardsCAN/CSA-B149.1or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.

In Australia and New Zealand, installation must comply with the Gas Installations Standard AS/NZS 5601 Part 1: General Installations.

WARNING

FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

W033

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building or area of all occupants.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

W052

IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-stepinstructions of the above safety information must be posted in a prominent location near the tumble dryer for customer use.

70420801 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

1

WARNING

Installation of unit must be performed by a qualified installer.

Install tumble dryer according to manufacturer’s instructions and local codes.

DO NOT install a tumble dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with tumble dryer. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct tumble dryer airflow and increase the risk of fire.

W752R1

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

W053

The following information applies to the state of Massachusetts, USA.

This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.

This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.

A "T-Handle"type gasshut-offvalve must be installed in the gas supply line to this appliance.

This appliance must not be installed in a bedroom or bathroom.

2

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70420801 (EN)

 

Introduction.........................................................................................

5

Table of

Model Identification .............................................................................

5

Contents

Wiring Diagram Location.....................................................................

5

 

Customer Service..................................................................................

5

 

Serial Plate Location.............................................................................

6

 

Safety Information..............................................................................

7

 

Important Safety Instructions ...............................................................

8

 

Specifications and Dimensions...........................................................

10

 

120 Pound Tumble Dryer Dimensions and

 

 

Exhaust Outlet Locations ...................................................................

11

 

170 Pound Tumble Dryer Dimensions and

 

 

Exhaust Outlet Locations ...................................................................

12

 

Electric and Gas Connection Locations for Gas Models......................

13

 

Electric and Steam Connection Locations for Steam Models ..............

14

 

Electric Connection Location for Electric Models ...............................

15

 

Installation...........................................................................................

16

 

Pre-Installation Inspection ....................................................................

16

 

Location Requirements.........................................................................

16

 

Position and Level the Tumble Dryer...................................................

18

 

Before Placing Tumble Dryer into Service ..........................................

18

 

Required for CE Models Only..............................................................

19

 

Installing CE Gas Drying Tumble Dryers ............................................

20

 

General Information.........................................................................

20

 

Basic Configuration .........................................................................

22

 

Specific Conversion Procedures ......................................................

23

 

Exhaust Requirements .......................................................................

25

 

Layout ...................................................................................................

25

 

Make-Up Air.........................................................................................

25

 

Venting .................................................................................................

25

 

Individual Venting ...........................................................................

27

 

Manifold Venting.............................................................................

27

 

Gas Requirements...............................................................................

31

 

Gas Supply Pipe Sizing and Looping ...................................................

33

 

High Altitude Orifice Sizing.................................................................

35

 

Electrical Requirements.....................................................................

36

 

Grounding Instructions .........................................................................

36

 

For CE Models Only........................................................................

37

 

Service/Ground Location......................................................................

38

 

To Connect Electrical Service to the Tumble Dryer........................

40

 

Jumper Configuration Instructions .......................................................

41

 

Ferrite Ring Installation........................................................................

41

 

Electrical Requirements........................................................................

42

© Copyright 2011, Alliance Laundry Systems LLC

All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.

70420801 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3

Steam Requirements...........................................................................

43

Piping Recommendations .....................................................................

43

Installing Steam Trap and Making Condensate

 

Return Connections ............................................................................

44

Thermal Oil Prep ..................................................................................

44

120 Pound Tumble Dryers....................................................................

45

170 Pound Tumble Dryers....................................................................

46

Adjustments.........................................................................................

47

Gas Burner Air Shutter .........................................................................

47

Airflow Switch......................................................................................

48

Loading Door Strike .............................................................................

48

Loading Door Switch............................................................................

48

Belt Drive..............................................................................................

49

Removing Tumble Dryer from Service.............................................

50

4

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70420801 (EN)

Introduction

Model Identification

Information in this manual is applicable to these models.

 

 

Gas

 

Steam/Thermal Oil

Electric

 

 

 

 

 

 

 

 

DR120G2-BA120L

HU120L

XT120L

DR120S2-BT120S

SU120S

DR120E2-BT120E

 

DR120G2-BA120N

HU120N

XT120N

DR120S2-BT120T

SU120T

DR120E2-BU120E

 

DR120G2-BT120L

IT120L

XU120L

DR120S2-BU120S

UT120S

CT120E

 

DR120G2-BT120N

IT120N

XU120N

DR120S2-BU120T

UT120T

CU120E

 

DR120G2-BU120L

SA120L

YT120L

CT120S

UU120S

HT120E

Pound

DR120G2-BU120N

SA120N

YT120N

CT120T

UU120T

HU120E

CA120L

ST120L

 

CU120S

XT120S

IT120E

CA120N

ST120N

 

CU120T

XT120T

ST120E

CT120L

SU120L

 

HT120S

XU120S

SU120E

120

 

CT120N

SU120N

 

HT120T

XU120T

UT120E

CU120L

UA120L

 

HU120S

YT120S

UU120E

 

 

 

CU120N

UA120N

 

HU120T

YT120T

 

 

HA120L

UT120L

 

IT120S

YU120S

 

 

HA120N

UT120N

 

IT120T

YU120T

 

 

HT120L

UU120L

 

ST120S

 

 

 

HT120N

UU120N

 

ST120T

 

 

 

 

 

 

 

 

 

 

DR170G2-BA170L

HU170L

XT170L

DR170S2-BT170S

SU170S

 

 

DR170G2-BA170N

HU170N

XT170N

DR170S2-BT170T

SU170T

 

 

DR170G2-BT170L

IT170L

XU170L

DR170S2-BU170S

UT170S

 

 

DR170G2-BT170N

IT170N

XU170N

DR170S2-BU170T

UT170T

 

 

DR170G2-BU170L

SA170L

YT170L

CT170S

UU170S

 

Pound

DR170G2-BU170N

SA170N

YT170N

CT170T

UU170T

 

CA170L

ST170L

 

CU170S

XT170S

 

CA170N

ST170N

 

CU170T

XT170T

Not Applicable

CT170L

SU170L

 

HT170S

XU170S

 

 

170

 

 

CT170N

SU170N

 

HT170T

XU170T

 

CU170L

UA170L

 

HU170S

YT170S

 

 

 

 

 

CU170N

UA170N

 

HU170T

YT170T

 

 

HA170L

UT170L

 

IT170S

 

 

 

HA170N

UT170N

 

IT170T

 

 

 

HT170L

UU170L

 

ST170S

 

 

 

HT170N

UU170N

 

ST170T

 

 

 

 

 

 

 

 

 

Includes models with the following control suffixes:

R3 – reversing DX4 OPL

RE – reversing OPL Micro

RQ – reversing dual digital timer

RD – reversing DMP OPL

RM – reversing OPL Micro

RU – reversing UniLinc OPL

Customer Service

If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950for the name and address of the nearest authorized parts distributor.

For technical assistance, call (920) 748-3121.

Wiring Diagram Location

The wiring diagram is located in the junction or contactor box.

The wiring diagram part number is in the lower portion of the electrical data on the serial plate.

70420801 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

Introduction

Serial Plate Location

When calling or writing for information about your product, be sure to mention model and serial numbers.

Model and serial numbers are located on the serial plate as shown.

1

120 POUND Tumble Dryer

1 Serial Plate

1

TMB2288N

170 POUND Tumble Dryer

TMB2288N

Conversion Table

Multiply

By

To Obtain

 

Multiply

By

To Obtain

 

 

 

 

 

 

 

Btu

0.252

kCal

 

Pounds/sq. inch

0.06895

Bars

 

 

 

 

 

 

 

Btu

1055

Joules

 

Pounds/sq. inch

0.070

kg/sq. cm

 

 

 

 

 

 

 

Inch

25.4

Millimeters

 

Pounds (lbs.)

0.454

Kilograms

 

 

 

 

 

 

 

Inches W.C.

0.036

Pounds/sq. inch

 

Boiler Horsepower

33,479

Btu/hr.

 

 

 

 

 

 

 

Inches W.C.

0.249

kPa

 

Boiler Horsepower

34.5

lbs. steam/hr.

 

 

 

 

 

 

 

lb./inch2 (psi)

6.895

kPa

 

CFM

0.471

liters/second

ft.3

28.32

Liters

 

kW

3414

Btu/hr.

6

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70420801 (EN)

Safety Information

Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.

DANGER

DANGER – Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.

WARNING

WARNING – Indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.

CAUTION

CAUTION – Indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.

Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.

IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.

NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.

WARNING

Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.

W051R1

NOTE: The WARNINGS and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumble dryer. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumble dryer.

Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.

70420801 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

7

Safety Information

Save These Instructions

Important Safety Instructions

WARNING

Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.

W359

1.Read all instructions before using the tumble dryer.

2.Refer to the Grounding Instructionsfor the proper grounding of the tumble dryer.

3.Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry cleaning solvents, other flammable or explosive substances as they give off vapors that could ignite or explode.

4.Do not allow children on or in the tumble dryer. This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

5.Before the tumble dryer is removed from service or discarded, remove the door to the drying compartment and the door to the lint compartment.

6.Do not reach into the tumble dryer if the cylinder is revolving.

7.Do not install or store the tumble dryer where it will be exposed to water and/or weather.

8.Do not tamper with the controls.

9.Do not repair or replace any part of the tumble dryer, or attempt any servicing unless specifically recommended in the user-maintenanceinstructions or in publisheduser-repairinstructions that you understand and have the skills to carry out.

10.Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

11.To reduce the risk of fire, DO NOT DRY plastics or articles containing foam rubber or similarly textured rubberlike materials.

12.Always clean the lint filter daily.

13.Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt.

14.The interior of the tumble dryer and the exhaust duct should be cleaned periodically by qualified service personnel.

15.If not installed, operated and maintained in accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer, birth defects or other reproductive harm.

16.Tumble dryer will not operate with the loading door open. DO NOT bypass the door safety switch to permit the tumble dryer to operate with the door open. The cylinder will stop rotating when the door is opened. Do not use the tumble dryer if the cylinder does not stop rotating when the door is opened or starts rotating without pressing or turning the START mechanism. Remove the tumble dryer from use and call for service.

17.Tumble dryer will not operate with lint panel open. DO NOT bypass lint panel safety switch to permit tumble dryer to operate with the lint panel open.

18.Do not put articles soiled with vegetable or cooking oil in the tumble dryer, as these oils may not be removed during washing. Due to the remaining oil, the fabric may catch on fire by itself.

19.To reduce the risk of fire, DO NOT put clothes which have traces of any flammable substances such as machine oil, flammable chemicals, thinner, etc. or anything containing wax or chemicals such as in mops and cleaning cloths, or anythingdry-cleanedat home withdry-cleaningsolvent in the tumble dryer.

20.Use the tumble dryer only for its intended purpose, drying fabrics.

21.ALWAYS disconnect the electrical power to the tumble dryer before servicing. Disconnect power by shutting off appropriate breaker or fuse.

8