Alliance Laundry Systems 70420801 User Manual

Size:
379.07 Kb
Download

Preliminary Installation Information

Subject

200 Pound Tumble Dryer

 

 

 

Use With 70420801 Installation Manual

 

 

Model Identification

 

 

 

 

 

 

 

 

 

 

 

Gas

 

Steam/Thermal Oil

 

 

 

 

 

 

 

DR200G2-BA200L

HA200N

UA200L

DR200S2-BT200S

HT200T

 

DR200G2-BA200N

HT200L

UA200N

DR200S2-BT200T

HU200S

 

DR200G2-BT200L

HT200N

UT200L

DR200S2-BU200S

HU200T

 

DR200G2-BT200N

HU200L

UT200N

DR200S2-BU200T

IT200S

 

DR200G2-BU200L

HU200N

UU200L

CT200S

IT200T

200 Pound

DR200G2-BU200N

IT200L

UU200N

CT200T

ST200S

CA200L

IT200N

 

CU200S

ST200T

 

CA200N

SA200L

 

CU200T

SU200S

 

CT200L

SA200N

 

HT200S

SU200T

 

CT200N

ST200L

 

 

UT200S

 

CU200L

ST200N

 

 

UT200T

 

CU200N

SU200L

 

 

UU200S

 

HA200L

SU200N

 

 

UU200T

 

 

 

 

 

 

Includes models with the following control suffixes:

R3 – reversing DX4 OPL RD – reversing DMP OPL

RE – reversing OPL Micro

RQ – reversing dual digital timer

RM – reversing OPL Micro

RU – reversing UniLinc OPL

Page 1 of 12

Part No. 70470101

September 2011

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Specifications and Dimensions

Specifications

200 Pound

 

 

Noise level measured during operation at operator position of 3.3 feet

66 dBA

(1 meter) in front of machine and 5.2 feet (1.6 meters) from floor.

 

 

 

Cylinder Size: Inches (mm)

50.75 x 50

(1289 x 1270)

 

 

 

Cylinder Capacity dry weight: Pounds (kg)

200

(90.7)

 

 

 

Cylinder Motor Horsepower

0.75

 

 

Fan Motor Horsepower

3

 

 

Air Outlet Diameter: Inches (mm)

12

(300)

 

 

 

Maximum Static Back Pressure: W.C.I. (mbar)

0.3

(0.8)

 

 

 

Maximum Airflow: C.F.M (L/sec.)

2450

(1156)

 

 

 

Gas Models

 

 

 

Net Weight (approximate): Pounds (kg)

1707

(774)

 

 

 

Gas Connection

1 in. NPT

 

 

Gas Burner Rating: Btu/hr. (Mj/hr.)

425,000

(448)

 

 

 

Steam Models

 

 

 

Net Weight (approximate): Pounds (kg)

1807

(820)

 

 

 

Steam Connection

3/4 in. NPT inlet

1 in. NPT outlet

 

 

 

Steam Coil Rating at 100 psig:Boiler Horsepower (Btu/hr.)

18.8

(recommended operating pressure 80-100psig)

(648,000)

 

 

Electric Models

 

 

 

Heating Element Rating:Kilowatts (kW)

N/A

 

 

N/A = Not Applicable

Page 2 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

200 Pound Tumble Dryer

Dimensions and Exhaust Outlet

Locations

TOP VIEW OF

EXHAUST

DUCT

X

 

W

Y

 

H

 

 

 

 

 

 

 

I

B

 

 

 

 

V

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TMB2363N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TMB2363N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabinet Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

A

 

 

B

 

 

 

C

 

 

 

 

D

 

 

 

E

 

 

 

 

F

 

 

 

 

G

 

 

 

 

 

H

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200L/N/S

32.1 in.

35.6 in.

 

58 in.

 

59.25 in.

 

76.18 in.

 

52.12 in.

 

 

53.12 in.

 

 

 

 

94 in.

 

75.12 in.

(815 mm)

(904 mm)

 

(1473 mm)

(1505 mm)

(1935 mm)

(1324 mm)

(1349 mm)

(2388 mm)

(1908 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to Position and Level the Tumble Dryer to temporarily reduce the heights of these models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust Outlet Dimensions and Locations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200L/N/S

 

 

 

 

 

67.19 in.

 

 

 

 

 

 

 

 

7.03 in.

 

 

 

 

9 in.

 

 

 

 

 

 

 

7 in.

 

 

 

 

(1707 mm)

 

 

 

 

 

 

 

(179 mm)

 

 

 

 

(229 mm)

 

 

 

 

 

(178 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 3 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electric and Gas Connection

Locations for Gas Models

A

C

 

D

 

B

TMB2357N

Models

Electrical Connection

 

Gas Connection

 

 

 

 

 

 

A

B

C

D

Diameter

 

 

 

 

 

 

 

200L/N

21 in.

81 in.

13.7 in.

77.4 in.

1 in. NPT

(533 mm)

(2057 mm)

(348 mm)

(1966 mm)

 

 

 

 

 

 

 

 

 

NOTE: These figures are approximate dimensions only.

Page 4 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electric and Steam Connection

 

 

 

Locations for Steam Models

 

 

 

 

A1

 

 

C

A2

 

 

 

B2

 

 

 

B1

 

 

 

E

F

 

 

D

 

 

 

 

 

TMB2358N

Models

Steam Inlet

 

 

A1

A2

F

Diameter

200S

3/4 in. NPT

37.625 in.

15.25 in.

88 in.

 

(956 mm)

(387 mm)

(2235 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

 

Steam Outlet

 

 

 

 

 

 

 

Diameter

B1

 

B2

D

 

 

 

 

 

 

 

 

200S

1 in. NPT

44.625 in.

 

8.75 in.

71.75 in.

 

(1133 mm)

 

(222 mm)

(1822 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

Electrical Connection

 

 

 

 

 

 

 

 

C

E

 

 

 

 

 

 

 

 

 

 

 

 

 

200S

21 in.

81 in.

 

 

 

(533 mm)

(2057 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 5 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Position and Level the Tumble Dryer

The tumble dryer may be moved with or without the skid. To remove the skid, unscrew the four shipping bolts, and discard them.

To fit a 200 pound tumble dryer (with shipping skid) through an 8 foot (2.43 meters) high door, you must remove the front access panel. The upper 3 inches (76 mm) of the stove must also be removed on

200 pound gas tumble dryers. Removing the entire gas or steam heater assembly and the shipping skid will reduce the height to 75 inches (1905 mm).

Level the tumble dryer to within 0.125 inch (3 mm) from front-to-rear(level on cylinder rib), andside-to-side (level on top panel). Shim under corners to level and stabilize unit. Tumble dryer must not rock.

Make-UpAir

Required Make-UpAir Opening (to the outside) for Each Tumble Dryer

Models

 

Opening

 

 

 

200 Pound

 

525 in.2 (3710 cm2)

 

free air

 

 

 

 

 

 

Table 1

Page 6 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Exhaust Requirements

1

 

 

 

 

 

 

 

 

 

 

 

 

2

L

K

J

I

H

G

F

E

D

C

B

A

3

ONE MANIFOLD ASSEMBLY

 

 

 

 

TMB2019N

1

NOTE: Where the exhaust duct pierces a

2

Outlet Duct Diameter

 

combustible wall or ceiling, the opening

3

45° Typical

 

MUST be sized per local codes.

 

 

 

 

 

 

 

 

 

 

 

Figure 1

 

 

 

 

 

 

 

Duct

 

 

200 Pound

 

Stations

 

 

12 in. (305 mm) Duct

 

 

 

 

 

 

 

 

 

 

A

 

 

12 in. (305 mm)

 

 

 

 

 

 

B

 

 

17 in. (432 mm)

 

 

 

 

 

 

C

 

 

21 in. (533 mm)

 

 

 

 

 

 

D

 

 

24 in. (610 mm)

 

 

 

 

 

 

E

 

 

27 in. (686 mm)

 

 

 

 

 

 

F

 

 

30 in. (762 mm)

 

 

 

 

 

 

G

 

 

32 in. (813 mm)

 

 

 

 

 

 

H

 

 

34 in. (864 mm)

 

 

 

 

 

 

I

 

 

36 in. (914 mm)

 

 

 

 

 

 

J

 

 

38 in. (965 mm)

 

 

 

 

 

 

K

 

 

40 in. (1016 mm)

 

 

 

 

 

 

L

 

 

42 in. (1067 mm)

 

 

 

 

 

Table 2

Page 7 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

1

2

I

J

K

L

L

K

J

I

CONTINUE

 

 

 

 

 

 

CONTINUE

TO A

 

 

 

 

 

 

TO A

 

 

 

 

3

 

 

TWO MANIFOLD ASSEMBLIES

 

 

 

 

TMB2018N

1

NOTE: Where the exhaust duct pierces a

2

Outlet Duct Diameter

 

combustible wall or ceiling, the opening

3

45° Typical

 

MUST be sized per local codes.

 

 

 

 

 

 

 

 

 

 

 

Figure 2

 

 

 

 

 

 

 

Duct

 

 

200 Pound

 

Stations

 

 

12 in. (305 mm) Duct

 

 

 

 

 

 

 

 

 

 

A

 

 

17 in. (432 mm)

 

 

 

 

 

 

B

 

 

24 in. (610 mm)

 

 

 

 

 

 

C

 

 

30 in. (762 mm)

 

 

 

 

 

 

D

 

 

34 in. (864 mm)

 

E

 

 

38 in. (965 mm)

 

 

 

 

 

 

F

 

 

42 in. (1067 mm)

 

 

 

 

 

 

G

 

 

45 in. (1143 mm)

 

 

 

 

 

 

H

 

 

45 in. (1143 mm)

 

 

 

 

 

 

I

 

 

52 in. (1321 mm)

 

 

 

 

 

 

J

 

 

54 in. (1372 mm)

 

K

 

 

57 in. (1448 mm)

 

 

 

 

 

 

L

 

 

60 in. (1524 mm)

 

 

 

 

 

Table 3

Page 8 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Gas Requirements

For converting Non-CEModels from Natural Gas to L.P. Gas:

200 Pound Models - M4975P3

High Altitude Orifice Sizing

For proper operation at altitudes above 2000 feet (610 meters), the gas orifice size must be reduced to ensure complete combustion. Refer to Table 4.

For CE models, consult local gas supplier.

Non-CEModels

 

 

Altitude

 

 

Orifice

 

 

New

Model

Gas

 

 

 

 

Rate

 

 

 

 

 

 

 

 

 

 

feet

m

No.

inches

mm

Quantity

Part No.

(Btu/hr.)*

 

 

2001 – 4000

610 – 1220

19

.1660

4.2

 

 

M402995

391,000

 

 

 

 

 

 

 

 

 

 

 

 

Natural

4001 – 6000

1221 – 1830

20

.1610

4.1

 

5

M401002

357,000

 

Gas

6001 – 8000

1831 – 2440

22

.1570

4.0

 

M402996

323,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200L/N

 

8001 – 10,000

2441 – 3050

24

.1520

3.9

 

 

M402980

289,000

 

 

 

 

 

 

 

 

 

 

 

2001 – 4000

610 – 1220

33

.1130

2.9

 

 

M401022

391,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L.P.

4001 – 6000

1221 – 1830

34

.1110

2.8

 

4

M411512

357,000

 

Gas

6001 – 8000

1831 – 2440

7/64

.1094

2.8

 

70070902

323,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8001 – 10,000

2441 – 3050

37

.1040

2.6

 

 

M401024

289,000

 

 

 

 

 

 

 

 

 

 

 

* Btu/hr. derate of 4% per 1000 ft. (305 m) of altitude.

Table 4

Page 9 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Requirements

For 200 Pound Tumble Dryer Models

Serial Plate Rating

Terminal Block

Rated

Breaker

Recommended Wire

Connections Required

Current*

Rating

Size

 

 

 

 

 

 

200-208V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

240V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

400-415V/50Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

440V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

460-480V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

* Current ratings vary slightly depending on model; refer to serial plate.

Table 5

Page 10 of 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT