Alliance Laundry Systems 70269701R4 User Manual

Size:
1.36 Mb
Download

Drying Tumblers

25 Pound Capacity

30 Pound Capacity

35 Pound Capacity Stacked 30 Pound Capacity

Through Serial No. 0602004143

Refer to Page 5 for Model Identification

NOTA: Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.

25

25

T477C

T478C

T477C

T478C

Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

 

 

 

www.comlaundry.com

Part No. 70269701R4

 

 

 

 

 

 

August 2006

Installation

Installation must conform with local codes or, in the absence of local codes, with:

In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”

In Canada, installation must comply with StandardsCSA-B149.1or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.

In Australia, installation must comply with the Australian Gas Association Installation Code for Gas Burning Appliances and Equipment.

WARNING

FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

W033

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building or area of all occupants.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

W052

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

W053

AVERTISSEMENT

POUR VOTRE SÉCURITÉ, les informations de ce guide doivent être respectées afin de réduire les risques d’incendie, d’explosion ou d’éviter les dommages matériels, personnels ou blessures mortelles.

W033Q3

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

Ne pas tenter d’allumer d’apareil.

Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous vous trouvez.

Évacuez la pièce, le bâtiment ou la zone.

Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.

L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.

W052Q

POUR VOTRE SÉCURITÉ

Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette unité ou de tout autre appareil.

W053Q2

IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-stepinstructions of the above safety information must be posted in a prominent location near the tumbler for customer use.

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

1

Notes

2

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70269701

 

Introduction.........................................................................................

5

Table of

Model Identification .............................................................................

5

 

Customer Service..................................................................................

7

Contents

Wiring Diagram ....................................................................................

7

 

Serial Plate Location.............................................................................

7

 

Safety Information..............................................................................

9

 

Important Safety Instructions ...............................................................

10

 

Specifications and Dimensions...........................................................

13

 

Cabinet Dimensions – 25, 30 and 35 Pound Models............................

14

 

Cabinet Dimensions – T30 ...................................................................

15

 

Exhaust Outlet Locations......................................................................

16

 

Gas Connection Locations....................................................................

17

 

Electrical Connection Locations...........................................................

18

 

Steam Connection Locations ................................................................

19

 

Installation...........................................................................................

21

 

Pre-Installation Inspection ....................................................................

21

 

Location Requirements.........................................................................

21

 

Tumbler Enclosure................................................................................

22

 

Position and Level the Tumbler............................................................

23

 

Installing Accessory Timing Cam ........................................................

24

 

Removal of Existing Timing Cam ...................................................

24

 

Installation of New Timing Cam .....................................................

24

 

Before Placing Tumbler into Service ...................................................

25

 

Required for CE Models Only .........................................................

25

 

Installing CE Gas Drying Tumblers .....................................................

26

 

General Information.........................................................................

26

 

Basic Configuration .........................................................................

29

 

Specific Conversion Procedures ......................................................

29

 

Exhaust Requirements .......................................................................

33

 

Layout ...................................................................................................

33

 

Make-Up Air.........................................................................................

33

 

Venting .................................................................................................

33

 

Individual Venting ...........................................................................

34

 

Manifold Venting.............................................................................

36

 

Gas Requirements...............................................................................

39

 

Gas Supply Pipe Sizing and Looping ...................................................

41

 

Electrical Requirements.....................................................................

45

 

Grounding Instructions .........................................................................

45

 

For CE Models Only........................................................................

45

 

Service/Ground Location......................................................................

46

 

Connecting Electrical Service...............................................................

47

 

Configuring Your Tumbler for Other Service Voltages ..................

47

 

Stacked Tumbler Electrical Connections.........................................

48

 

Conversion Instructions ........................................................................

49

 

Ferrite Ring Installation........................................................................

51

 

Electrical Requirements for Gas and Steam Models ............................

52

© Copyright 2006, Alliance Laundry Systems LLC

All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3

Electrical Requirements for Electric Models........................................

54

Steam Requirements...........................................................................

57

Piping Recommendations .....................................................................

57

Installing Steam Trap and Making Condensate Return Connections...

58

Adjustments.........................................................................................

61

Loading Door Switch............................................................................

61

Airflow Switch......................................................................................

62

Door Strike............................................................................................

62

Removing Tumbler from Service......................................................

63

4

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70269701

Introduction

Model Identification

Information in this manual is applicable to these models.

 

 

Gas

 

Steam

Electric

 

 

 

 

 

 

 

CHD25G2-CA025L

HA025N

ST025L

CHD25S2-CT025S

CHD25E2-CT025E

 

CHD25G2-CA025N

HT025L

ST025N

CHD25S2-CU025S

CHD25E2-CU025E

 

CHD25G2-CT025L

HT025N

SU025L

DR25S2-BT025S

DR25E2-BT025E

 

CHD25G2-CT025N

HU025L

SU025N

DR25S2-BU025S

DR25E2-BU025E

 

CHD25G2-CU025L

HU025N

UA025L

HT025S

HT025E

25 Pound

CHD25G2-CU025N

IPD25G2-IA025L

UA025N

HU025S

HU025E

DR25G2-BA025L

IPD25G2-IA025N

UT025L

IPD25S2-IT025S

IPD25E2-IT025E

 

DR25G2-BA025N

IPD25G2-IT025L

UT025N

IPD25S2-IU025S

IPD25E2-IU025E

 

DR25G2-BT025L

IPD25G2-IT025N

UU025L

ST025S

ST025E

 

DR25G2-BT025N

IPD25G2-IU025L

UU025N

SU025S

SU025E

 

DR25G2-BU025L

IPD25G2-IU025N

YT025L

UT025S

UT025E

 

DR25G2-BU025N

SA025L

YT025N

UU025S

UU025E

 

HA025L

SA025N

 

YT025S

YT025E

 

 

 

 

 

 

 

CHD30G2-CA030L

HU030L

ST030N

CHD30S2-CT030S

CHD30E2-CT030E

 

CHD30G2-CA030N

HU030N

SU030L

CHD30S2-CU030S

CHD30E2-CU030E

 

CHD30G2-CT030L

IPD30G2-IA030L

SU030N

HT030S

HT030E

 

CHD30G2-CT030N

IPD30G2-IA030N

UA030L

HU030S

HU030E

30 Pound

CHD30G2-CU030L

IPD30G2-IT030L

UA030N

IPD30S2-IT030S

IPD30E2-IT030E

CHD30G2-CU030N

IPD30G2-IT030N

UT030L

IPD30S2-IU030S

IPD30E2-IU030E

 

HA030L

IPD30G2-IU030L

UT030N

ST030S

ST030E

 

HA030N

IPD30G2-IU030N

UU030L

SU030S

SU030E

 

HT030D

SA030L

UU030N

UT030S

UT030E

 

HT030L

SA030N

YT030L

UU030S

UU030E

 

HT030N

ST030L

YT030N

YT030S

YT030E

 

 

 

 

 

 

 

CHD30STG2-CAT30L

HAT30N

NTT30N

CHD30STS2-CTT30S

CHD30STE2-CTT30E

 

CHD30STG2-CAT30N

HTT30D

SAT30L

CHD30STS2-CUT30S

CHD30STE2-CUT30E

 

CHD30STG2-CTT30L

HTT30L

SAT30N

DRST30S2-BTT30S

DRST30E2-BTT30E

 

CHD30STG2-CTT30N

HTT30N

STT30L

DRST30S2-BUT30S

DRST30E2-BUT30E

 

CHD30STG2-CUT30L

HUT30L

STT30N

HTT30S

HTT30E

T30

CHD30STG2-CUT30N

HUT30N

SUT30L

HUT30S

HUT30E

DRST30G2-BAT30L

IPD30STG2-IAT30L

SUT30N

IPD30STS2-ITT30S

IPD30STE2-ITT30E

 

DRST30G2-BAT30N

IPD30STG2-IAT30N

 

IPD30STS2-IUT30S

IPD30STE2-IUT30E

 

DRST30G2-BTT30L

IPD30STG2-ITT30L

 

STT30S

STT30E

 

DRST30G2-BTT30N

IPD30STG2-ITT30N

 

SUT30S

SUT30E

 

DRST30G2-BUT30L

IPD30STG2-IUT30L

 

 

 

 

DRST30G2-BUT30N

IPD30STG2-IUT30N

 

 

 

 

HAT30L

MTT30N

 

 

 

 

 

 

 

 

 

Table (continued)

NOTE: Control suffixes listed on next page.

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

Introduction

Table (continued)

 

 

Gas

 

Steam

Electric

 

 

 

 

 

 

 

AT035L

HA035N

SU035L

AT035S

CHD35E2-CT035E

 

AT035N

HT035L

SU035N

CHD35S2-CT035S

CHD35E2-CU035E

 

CHD35G2-CA035L

HT035N

UA035L

CHD35S2-CU035S

DR35E2-BT035E

 

CHD35G2-CA035N

HU035L

UA035N

DR35S2-BT035S

DR35E2-BU035E

 

CHD35G2-CT035L

HU035N

UT035L

DR35S2-BU035S

HT035E

 

CHD35G2-CT035N

IPD35G2-IA035L

UT035N

HT035S

HU035E

35 Pound

CHD35G2-CU035L

IPD35G2-IA035N

UU035L

HU035S

IPD35E2-IT035E

CHD35G2-CU035N

IPD35G2-IT035L

UU035N

IPD35S2-IT035S

IPD35E2-IU035E

 

DR35G2-BA035L

IPD35G2-IT035N

YT035L

IPD35S2-IU035S

ST035E

 

DR35G2-BA035N

IPD35G2-IU035L

YT035N

ST035S

SU035E

 

DR35G2-BT035L

IPD35G2-IU035N

 

SU035S

UT035E

 

DR35G2-BT035N

SA035L

 

UT035S

UU035E

 

DR35G2-BU035L

SA035N

 

UU035S

YT035E

 

DR35G2-BU035N

ST035L

 

YT035S

YU035E

 

HA035L

ST035N

 

YU035S

 

 

 

 

 

 

 

Includes models with control suffixes:

3O – DX4 OPL

3V – DX4 vended

3X – DX4 prep for coin BC – basic electronic, coin

BL – basic electronic, central pay BX – basic electronic, prep for coin BY – basic electronic, prep for card CD – rotary coin drop

CX – prep for coin

CY – prep for card DO – DMP OPL DV – DMP vended

DX – DMP prep for coin EC – EDC electronic coin EX – EDC coin ready EY – EDC card ready MT – manual timer

NC – NetMaster coin

NR – NetMaster card

NX – NetMaster, prep for coin NY – NetMaster, prep for card OM – OPL micro

ZC – NetMaster network coin ZR – NetMaster network card

ZX – NetMaster network, prep for coin ZY – NetMaster network, prep for card

6

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70269701

Customer Service

If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950for the name and address of the nearest authorized parts distributor.

For technical assistance, call (920) 748-3121.

Serial Plate Location

When calling or writing for information about your product, be sure to mention model and serial numbers. Model and serial numbers are found on serial plate on rear of machine, and inside the loading door hinge.

Introduction

Wiring Diagram

The wiring diagram is inside the junction or contactor box.

Models starting Serial No. 0309_____ or later will have the wiring diagram part number in the lower portion of the electrical data on the serial plate.

25, 30 AND 35 POUND

1

 

 

1

T30

TMB2025N

TMB2025N

1 Serial Plate

Conversion Table

Multiply

By

To Obtain

 

Multiply

By

To Obtain

 

 

 

 

 

 

 

Btu

0.252

kCal

 

Pounds/sq. inch

0.06895

Bars

 

 

 

 

 

 

 

Btu

1055

Joules

 

Pounds/sq. inch

0.070

kg/sq. cm

 

 

 

 

 

 

 

Inch

25.4

Millimeters

 

Pounds (lbs.)

0.454

Kilograms

 

 

 

 

 

 

 

Inches W.C.

0.036

Pounds/sq. inch

 

Boiler Horsepower

33,479

Btu/hr.

 

 

 

 

 

 

 

Inches W.C.

0.249

kPa

 

Boiler Horsepower

34.5

lbs. steam/hr.

 

 

 

 

 

 

 

lb/inch2 (psi)

6.895

kPa

 

CFM

0.471

liters/second

ft3

28.32

Liters

 

kW

3414

Btu/hr.

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

7

Notes

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70269701