Never obstruct the air vents located at the left and right sides of the chassis.

Note. Clearance is not required at the top and bottom of the chassis. For detailed chassis airflow diagrams, refer to theOmniSwitch 6850 Series Hardware Users Guide.

Installation Options

There are two ways in which the OmniSwitch 6850 Series switches can be installed:

Tabletop installation

Rack-mountinstallation

For information on setting up a switch as a tabletop unit, refer to “Installing the Switch on a Tabletop or Bench.” For information on rack-mountingthe switch, refer to“Rack-Mounting the Switch” on page 8.

Installing the Switch on a Tabletop or Bench

OmniSwitch 6850 Series switches can be installed freestanding as tabletop units. Place your switch on a stable, flat, and static-freesurface.

Note. OmniSwitch 6850 Series switches must be placed “right side up.” Never attempt to operate a switch positioned on its side.

Tabletop Mounting Steps

To install the switch as a tabletop unit, follow the steps below:

1Position the chassis on the table or bench where it is to be installed.

2Be sure that adequate clearance has been provided for chassis airflow and access to the front, back, and sides of the switch. For recommended clearances, refer to page 6. Also, be sure that you have placed the chassis within reach of all required AC power sources.

If you are placing multiple switches in a stacked configuration, carefully stack the remaining switches, one on top of the other. Up to eight switches may be stacked to form a single virtual chassis. Be sure to maintain adequate clearance at the front, rear, left, and right side of all switches (see page 6). Also, be sure that you have placed all switches in the stack within reach of required AC power sources.

Note. If you are installing a single (i.e., standalone) switch, continue to“Connections and Cabling” on page 11 for additional setup procedures.

June 2007

Installing the Hardware 7