T r a n s p o r t S e r v i c e S w i t c h | R e l e a s e 3

The Alcatel-Lucent1850TSS-160is a compact version of theAlcatel-LucentTSS-320.The two models share the universal switch matrix architecture, operate on a common software release and use common circuit packs. TheAlcatel-Lucent1850TSS-160is anext-generation,Packet-OpticalTransport platform that supports any mix of traffic, fromall-circuittoall-packet.With theAlcatel-Lucent1850TSS-160,businesses can begin withcircuit-basedtransport and gradually ramp up packet transport by simply changing line cards. The AlcatelLucent 1850TSS-160supports current traffic requirements while eliminating the scalability issues encountered when traditional multiservice provisioning platforms (MSPPs) are confronted with the high growth of packetbased traffic.

The Alcatel-Lucent1850TSS-160offers the flexibility to split increasing traffic demands among any combination of Carrier Ethernet, Transport MultiProtocol Label Switching(T-MPLS),wavelength division multiplexing (WDM), optical data unit (ODU) and SDH/SONET transport technologies. It offers powerfulcross-layernetwork management and a unifiied control plane, simplifying operations and reducing the total cost of ownership.

Features

Common software and circuit packs with Alcatel-Lucent1850TSS-320

Unique, universal switch architecture

¬Switches packets or circuits in their native format

¬Accommodates any traffic mix, from all-circuittoall-packet

¬Offers TDM and packet line cards for technology-specifiicprocessing

Fully integrates photonic, optical and data layers

¬Any transport-technologymix

¬Carrier Ethernet service through T-MPLSforstandards-basedcon-nection-orientedpacket transport

¬SONET/SDH Optical Transport Hierarchy (OTH) switching, including higher-orderandlower-order(HO/LO) synchronous transport signal (STS) andVC-switching

¬Very long haul (VLH)/ultra long haul (ULH) support

¬ATM pseudo-wiretransport and gateway functions

¬Dense WDM (DWDM)

¬Transport-orientedOAM andG-MPLS

Delivers multidegree reconfigurable optical add/drop multiplexer (ROADM) functionality

¬Reconfigurable 44 x 10 G channel DWDM

¬Wavelength selective switch (WSS)

1x 9 ports

¬Mesh capable ROADM up to

8degrees

Benefits

Switches any combination of packets and circuits in their native formats using a single platform

Fully scales packet transport, smoothly progressing from all-circuitto allpacket, allowing service providers to transform networks to packet transport

Efficiently aggregates and grooms metro and long-haultransport

Simplifies network planning using

ROADM and WDM

Reduces total cost of ownership and simplifies operations through crosslayer network management and unified control plane

Supports a broad range of applications, such as triple play services, business Ethernet and mobility backhaul

Technical specifications

Alcatel-Lucent1850TSS-160system

Alcatel-Lucent1850TSS-160subrack

8 slots, 20 Gb/s per slot: 16 half slots, 10 Gb/s per half slot

Two 160 Gb/s protected switching fabrics

Two protected controllers

Protected power supply

Up to three subracks in a standard

ETSI or ANSI rack

Interfaces

Data cards

¬10 x Gigabit Ethernet (GE) packet module, Small FormFactor Pluggable (SFP)

¬10 GE packet module, 10 Gb/s

Form-FactorPluggable (XFP)

¬Multiservice packet over

SONET/SDH (PoS) packet module, portless

¬ATM gateway packet module, portless

SONET/SDH cards

¬1 x OC-192/STM-64:XFP

¬4 x OC-48/STM-16:SFP

¬8 x OC-3-12/STM-1-4:SFP

¬10 x any port card: a data/TDM concentrator: SFP

¬1 x optical transport unit

(OTU)-2:10 Gb/s bidirectional transponder, tunable optics

VLH/ULH cards

¬10 Gb/s booster +10 dBm

¬10 Gb/s pre-amp+10 dBm

Fixed OADM (FOADM) DWDM cards (packs)

¬8 channels MUX/DEMUX,

L1 band

¬8 channels MUX/DEMUX,

L2 band

¬Optical amplifier 22/9 17 dB

¬10 G transponder, client and line pluggable: XFP

ROADM DWDM cards (packs)

¬Optical protection switch

¬DWDM ROADM wavelength router

¬DWDM transponder: tunable line optics, XFP client

¬DWDM MUX/DEMUX

¬DWDM amplifier

Service level agreement (SLA) management

Traffic profiles

¬Bandwidth guaranteed

¬Regulated: minimum bandwidth guaranteed plus burst

¬Best effort

Hitless traffic-profilemodification

Metering

¬Single Rate Token Bucket: RFC 2697

¬Dual Rate Token Bucket:

RFC 2698

¬IETF and Metro Ethernet Forum (MEF) Metering, Policing and Marking

¬Color-blindandcolor-aware,based on Ethernet priority bits

Ethernet functionality

Ethernet protocol: 802.3

Ethernet Media Access Control

(MAC) autolearning and aging

Ethernet-MACstatic configuration

Access Control List (ACL)

Virtual LAN (VLAN) push, pop, swap: service delimiting

Ethernet virtual bridging: 802.1Q

Ethernet provider bridging: 802.1ad

Q in Q

Rapid Spanning Tree Protocol

(RSTP) and Multiple Spanning Tree Protocol (MSTP)

Link aggregation

Jumbo-framemanagement

Y.1731/802.1ag OAM: continuity check (CC), link trace (LT), loopback (LB)

802.3ah OAM: Ethernet in the first mile (EFM)

Eight Quality of Service (QoS) classes

Two levels QoS: per class, per transport service

Ethernet flow, RGY counters

L2 control protocol filtering/ tunneling

Metro Ethernet Forum (MEF) 9 and MEF 14 certified: EPL, EVPL and E-LAN

Ethernet traffic classification

Port

Ethernet VLAN

Ethernet priority bits

IP v4 differentiated services code points (DSCP)

EtherType

MPLS Exp bits

2 Alcatel-Lucent1850TSS-160| Release 3 | Data Sheet

Ethernet forwarding criteria

Port

Port plus MAC

Port plus VLAN

Port plus MAC plus VLAN

Port plus MAC plus VLAN plus

Prio bits

Unicast traffic

Multicast traffic

Broadcast traffic

IGMP functionality

Internet Group Management Protocol (IGMP) snooping

IGMP proxy

IGMP fast leave

ATM functionality

Pseudo-wireemulation edge to edge (PWE3):ATM-PWE3gateway

OC-3/STM-1ATM unchannalized

ATM virtual path identifier/virtual channel identifier (VPI/VCI)

N:1 mapping with PWE3 static configuration

ATM QoS, OAM F4, F5: PWE OAM

T-MPLSfunctionality

Data plane: T-MPLS,MPLS

T-MPLSOAM: CV, automatic protection switching (APS), forward defect indication (FDI)

Tunnel Lin Protection 1:1

Ethernet line (E-line),E-LANandE-Tree

SONET/SDH functionality

Cross-connection

Termination

Ethernet mapping over SONET/SDH

¬Generic framing procedure: GFP, G.7041

Virtual concatenation (VCAT)

Link capacity adjustment scheme

(LCAS)

Performance monitoring

HO and LO capabilities

DWDM functionality

Node configurations

¬Terminal

¬In-lineamplifier (ILA)

Network configurations

¬Point-to-point

¬Linear

¬Ring

¬Mesh

Protection

Ethernet network protection

¬RSTP: 802.1w

¬MSTP: 802.1s

¬Link aggregation

T-MPLSnetwork protection

¬Tunnel Lin Protection 1:1

SONET/SDH network protection

¬Singleand dual-endedAPS 1 + 1

¬Subnetwork Connection Protocol (SNCP), unidirectional path-switchedring (UPSR)

¬Multiplex Section-Protection

Ring (MSPRING) 2F bidirectional line switching ring (BLSR)

Equipment protection

¬Power protection

¬Controller protection

¬Universal switch protection

G-MPLScontrol plane

T-MPLStunnel setup

TDM HO path setup

Management

Alcatel-Lucent1350 Optical

Management System (OMS)

TL1

Zero-installationcraft (ZIC) terminal

Command line interface (CLI)

Simple Network Management

Protocol (SNMP)

Secure Shell (SSH) v2/Secure

Sockets Layer (SSL) for secure connection

Physical specifications

ANSI

Dimensions: Alcatel-Lucent1850TSS-160subrack

Subrack dimensions

¬Height: 304 mm (12.0 in.)

¬Width: 498 mm (19.6 in.)

¬Depth: 305 mm (12.0 in.) or 356 mm (14.0 in.)

Designed to be installed in a standard ANSI rack

¬Height: 2.13 m (7.0 ft.)

¬Width: 660 mm (26.0 in.)

¬Depth: 305 mm (12.0 in.) or 356 mm (14.0 in.)

Power and cooling

Power supply: DC feed (-48-VDC nominal)

Power supply: -58-V

Power consumption: up to 2000 W

Cooling: forced air

Environment

Operating temperature:

-5°Cto +45°C (23°F to 113°F)

Relative humidity: 0% to 90%, non-condensed

Regulatory compliance

CE and UL certification

NEBS level 3

FCC part 15 class A

ETSI

Dimensions: Alcatel-Lucent1850TSS-160subrack

Subrack dimensions

¬Height: 304 mm (12.0 in.)

¬Width:498 mm (19.6 in.)

¬Depth: 290 mm (11.4 in.)

Designed to be installed in a standard ETSI rack

¬Height: 2.20 m (7.2 ft.)

¬Width: 600 mm (23.6 in.)

¬Depth: 300 mm (11.8 in.)

Power and cooling

Power supply: DC feed (-48-VDC nominal)

Power supply: -65-V

Power consumption: up to 2000 W

Cooling: forced air

Environment

Operating temperature:

-5°Cto +45°C (23°F to 113°F)

Relative humidity: 0% to 90%, non-condensed

Regulatory compliance

CE certification

Operating conditions:

ETS 300 019, Class 3.2

Storage conditions:

ETS 300 019, Class 1.2

Transportation conditions:

ETS 300 019, Class 2.2

Electrostatic discharge (ESD)/electromagnetic compatibility (EMC):

ETS 300 386 “Telecommunications Center”

Alcatel-Lucent1850TSS-160| Release 3 | Data Sheet

3

www.alcatel-lucent.com Alcatel, Lucent,Alcatel-Lucentand theAlcatel-Lucentlogo are trademarks ofAlcatel-Lucent.All other trademarks are the property of their respective owners. The information presented is subject to change without notice.Alcatel-Lucentassumes no responsibility for inaccuracies contained herein. Copyright © 2008Alcatel-Lucent.All rights reserved.

CAR4688080916 (09)