Air King Exhaust Fan with Light DRLC709 User Manual

Size:
258.95 Kb
Download

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

Models: DRLC701, DRLC702,

Exhaust Fan with Light

DRLC703, DRLC709

 

 

 

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

1.Read all instructions before installing or using exhaust fan.

2.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

3.Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-relatedconstruction.

5.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.

CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Ducted fans must always be vented to the outdoors.

8.This unit must be grounded.

9.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANYSOLID-STATESPEED CONTROL DEVICE.

10.Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit.

11.NEVER place a switch where it can be reached from a tub or shower.

WARNING: DO NOT USE IN KITCHENS

SAVE THESE INSTRUCTIONS

210572063 Rev. A 8-05

www.airkinglimited.com

1 of 12

INSTALLATION INSTRUCTIONS

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have:

1 - Grill with Glass Light Lens

1 - Damper Assembly (attached)

2 - #8 Screws

2 - Lockwashers

4 - Mounting Rails

1 - Instruction/Safety Sheet

2.Remove the fan’s venturi assembly, which is secured in place with one screw through the venturi (Figure 1). This is a captive screw and will stay installed in the venturi. Keep the venturi assembly and the grill in the carton until needed so they do not get damaged or lost.

Screw

Figure 1

3.Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 6" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The

fan can be mounted directly to the joist using the mounting tabs on the sides of the housing or between 16" on center joists using the 4 provided mounting rails.

4.Select the most convenient electrical knockout and remove

using a straight-bladescrew driver

Figure 2

(Figure 2).

 

SECTION 2

New Construction

1.Mounting Rail Installation: Install the rails on the housing and position the housing next to the joist. Using the gauge on the fan’s housing, line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position(Figure 3).

Housing

 

 

Joist

Figure 3

Hanger Bar

 

2.Mounting Tab Installation: Using the gauge on the fan’s housing, line up housing so that it will be flush with the finished ceiling. Position the fan so that the tabs rest flat against the joist and secure with four nails or screws (not provided) to ensure proper installation(Figure 4).

/ "

5 8

/ "

1 2

/ "

3 8

/ "

1 4

Figure 4

SECTION 3

Existing Construction

1a. Mounting Rail Installation: Set housing in position between the joist and trace an outline onto the ceiling material(Figure 5). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists with nails or screws (not provided)(Figure 3).

Figure 5

1b. Mounting Tab Installation: Position housing against the joist and trace an outline of the housing onto the ceiling material(Figure 6). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Place housing next to the joist and insure that it is flush with the finished ceiling. Secure with four nails or screws (not provided) to ensure proper installation(Figure 4).

210572063 Rev. A 8-05

www.airkinglimited.com

2 of 12

Figure 6

SECTION 4

Ducting

CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES.

1.Connect the ducting to the fan’s duct collar (Figure 7). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.

Figure 7

NOTE: If damper detaches from unit, reattach by snapping the collar back onto the unit. It is designed to only fit one way.

SECTION 5

Wiring

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.Wiring Fan/Light Independently: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and two hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.

1a. From where you have access to inside the fan’s junction box, connect the one white wire from the house to both the white wire from the fan’s light receptacle and the white wire from the fan’s exhaust receptacle. Connect the first black wire from the wall switch to the black wire from the fan’s light receptacle. Connect the second black wire from the house to the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 8). Use approved methods for all connections.

Supply

Ground

from

 

house

White

 

Figure 8

Hot (Black)

 

2.Wiring Fan/Light together: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.

2a. From where you have access to inside the fan’s junction box, connect the one white wire from the house to both the white wire from the fan’s light receptacle and the white wire from the fan’s exhaust receptacle. Connect the black wire from the wall switch to both the black wire from the fan’s light receptacle and the black wire from the fan’s exhaust receptacle. Connect the ground wire from the house to the green wire from the fan’s grounding screw (Figure 9). Use approved methods for all connections.

Supply

Ground

from

 

house

 

 

White

Figure 9

Hot (Black)

 

SECTION 6

Completing the Installation

1.Reinstall the fan’s venturi by holding it at approximately a 45 degree angle, hook the two tabs on the venturi into the slots on the housing and secure in place by tightening the venturi screw. Rotate the blower wheel by hand to ensure it spins freely. Now plug the fan motor into the receptacle (Figure 10).

Figure 10

2.Remove glass light lens from grill by unscrewing knob at the top of lens (Figure 11).

210572063 Rev. A 8-05

www.airkinglimited.com

3 of 12

Glass Lens

 

Figure 11

Knob

 

3.Plug cord from lamp holders into the appropriate receptacle

(Figure 12).

 

Cord

 

Lamp

Figure 12

Holders

4.Line up slots in the grill with lances on inside of housing. Insert included #8 screws through grill slots and into housing lances. Tighten both screws until the grill fits snugly to the ceiling. DO NOT OVER TIGHTEN (Figure 13).

 

Lances

 

Grill

Figure 13

#8 Screws

CAUTION: FAILURE TO SECURE THE GRILL MAY RESULT IN A RATTLING OR HUMMING NOISE.

5.Install 2 - 60 watt maximum, type A19 medium base incandescent bulbs (not included).

6.Reinstall the glass lens in place by sliding the hole in the lens onto the rod from the grill and securing in place with the lens knob (Figure 14).

Grill

Rod

Glass Lens

 

Hole

Knob

Figure 14

 

7. Restore power and test your installation.

SECTION 7

Use and Care

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.

1.Cleaning the Grill: Refer to instructions in Section 6

Completing the Installation, to remove grill and glass light lens. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry all parts before reinstalling. Refer to instructions inSection 6 Completing the Installation, to reinstall grill and glass light lens.

2.Cleaning the Fan Assembly: Unplug the motor cord and light cord from receptacles and loosen the venturi screw to remove the venturi from the unit. Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. Refer to instructions inSection 6 Completing the Installation, to reinstall venturi.

CAUTION: ALLOW BULB TO COOL BEFORE REPLACING.

3.Changing the Light Bulb: Disconnect power to the unit. Remove glass light lens from grill by unscrewing knob at the top of lens(Figure 11). Replace light bulb(s) with 60 watt maximum, type A19 medium base incandescent bulb(s). Reinstall the glass lens in place by sliding the hole in the lens onto the rod from the grill and securing in place with the lens knob (Figure 14).

210572063 Rev. A 8-05

www.airkinglimited.com

4 of 12

Troubleshooting Guide

 

Trouble

 

Probable Cause

 

Suggested Remedy

1.

Fan does not operate when the switch is on.

1a.

A fuse may be blown or a circuit tripped.

1a.

Replace fuse or reset circuit breaker.

 

 

1b.

Connector plug from motor is not plugged in.

1b.

Turn off power to unit. Remove Grill and plug motor into receptacle

 

 

 

 

 

in housing. Restore power to unit.

 

 

1c.

Wiring is not connected properly.

1c.

Turn off power to unit. Check that all wires are connected.

 

 

1d.

Motor has stopped operating.

1d.

Replace motor.

 

 

 

 

 

2.

Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2. Check for any obstructions in the ducting. The most common are bird nests

 

 

 

 

 

in the roof cap or wall cap where the fan exhausts to the outside.

 

 

 

 

 

 

3.

Fan is operating louder than normal.

3a.

Motor is loose.

3a.

Turn off power to unit. Remove grill and check that all screws are fully

 

 

 

 

 

tightened. Restore power to unit.

 

 

3b.

Fan blade is hitting housing of unit.

3b.

Call your dealer for service.

LIMITED WARRANTY

All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material.

This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty installation, or improper maintenance will not be covered by this warranty.

In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.

Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

FOR PARTS OR TECHNICAL ASSISTANCE

Please call: 1-800-465-7300, MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.

PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.

Reference the type and style of product (located on label inside of the product) when you call. For more information please visit our website: wwwairkinglimited.com

Installer: _________________________________________________________

Installation Date:_________________________________________

Place of Purchase: _________________________________________________

Model Number: __________________________________________

210572063 Rev. A 8-05

www.airkinglimited.com

5 of 12

REPLACEMENT PARTS DIAGRAM

11

17

1

2

3

 

4

 

9

 

 

10

 

 

8

5

12

 

6

 

24

23

 

 

 

22

7

13

 

 

18

21

14

19

20

15

 

 

18

16

#

Qty.

Description

Replacement Part #

1

1

Fan Housing

5S1201009

2

4

Mounting Rails

5S1299002

3

1

Collar

5S1201010

4

1

Damper

5S1201011

5

1

Polarized Receptacle

5S1999001

6

1

#8 Screw

5S1999004

7

1

Polarized Nylon Receptacle 2P

5S1201012

8

1

Goose Neck Wire Cover

5S1201004

9

1

#10 Ground Screw

5S1999002

10

1

14 ga Ground Wire

5S1999003

11

1

Scroll

5S1201006

12

1

Motor Plate

5S1201014

13

1

Impeller

5S1299001

14

2

Hex Nut

5S1999006

15

1

Motor

5S2201003

#

Qty.

Description

Replacement Part #

16

1

Knob - Bronze

5S5204101

 

1

Knob - Nickel

5S5204201

 

1

Knob - White

5S5204301

 

1

Knob - Brass

5S5204901

17

1

Lamp Holder

5S5204002

18

1

Glass Lens

5S5204003

19

2

Mounting Screws

5S5204004

20

1

Mounting Rod

5S5204005

21

1

Base - Bronze

5S5204106

 

1

Base - Nickel

5S5204206

 

1

Base - White

5S5204306

 

1

Base - Brass

5S5204906

22

1

Lockwasher

5S5204007

23

1

Nut

5S5204008

24

1

Captive Screw

5S1999005

210572063 Rev. A 8-05

www.airkinglimited.com

6 of 12

INSTRUCTIONS IMPORTANTES –

MANUEL D’OPÉRATION

Modèles: DRLC701, DRLC702,

Ventilateur combiner, comprend

DRLC703, DRLC709

lumière et ventilation

LIRE ET CONSERVER CES INSTRUCTIONS

LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊMEET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À LA PROPRIÉTÉ.

CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.

INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ

Lors de l’utilisation d’appareils électriques, des précautions de base doivent toujours être suivies pour réduire les risques d’incendie, de choc électrique et de blessures corporelles, incluant ce qui suit:

1.Bien lire toutes les instructions avant d’installer ou d’utiliser le ventilateur d’évacuation.

2.Utiliser cette unité seulement de la manière pour laquelle le fabricant l’a conçu. Si vous aviez des questions, veuillez contacter le fabricant.

3.Avant d’effectuer un service ou de nettoyer l’unité, couper l’alimentation électrique dans le panneau de distribution et verrouiller le dispositif de déconnexion afin d’éviter que l’alimentation ne revienne accidentellement. Lorsque le dispositif ne peut être verrouillé, fixer solidement un avis d’avertissement, tel qu’une étiquette, au panneau de distribution.

4.Le travail d’installation et le câblage électrique doivent être effectués par une(des) personne(s) qualifiée(s) en conformité avec tous les codes et normes applicables, incluant la construction relative aux incendies.

5.De l’air en quantité suffisante est requis pour la bonne combustion et l’évacuation de gaz par le conduit (cheminée) provenant d’équipement de brûlage au combustible pour prévenir un refoulement. Suivre les directives du fabricant de l’équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association (NFPA) et de la American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), et de celles des autorités locales du code.

AVERTISSEMENT: POUR USAGE DE VENTILATION GÉNÉRALE EXCLUSIVEMENT. NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES.

6.Lors de coupe ou de perçage des murs et plafonds, ne pas endommager le filage électrique et autres utilités cachées.

7.Les ventilateurs avec conduits doivent toujours être évacués vers l’extérieur.

8.Cette unité doit être mise à la terre.

9.Pour éviter des dommages aux roulements des moteurs et/ou des hélices bruyantes ou déséquilibrées, empêcher la poussière de cloison sèche, poussière de construction, etc., d’atteindre l’unité de puissance.

AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE CHOC ÉLECTRIQUE, NE PAS UTILISER CE VENTILATEUR AVEC UN RÉGULATEUR DE VITESSE ÉLECTRONIQUE.

10.Acceptable pour utilisation au-dessusd’une baignoire ou d’une douche lorsque installé dans un circuit protégé par un disjoncteur de fuite de terre.

11.NE JAMAIS placer un interrupteur à un endroit qui puisse être atteint de la baignoire ou de la douche.

AVERTISSEMENT: NE PAS UTILISER DANS LES CUISINES

CONSERVER CES INSTRUCTIONS

210572063 Rev. A 8-05

www.airkinglimited.com

7 of 12

INSTRUCTIONS D’INSTALLATION

 

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION

 

EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER

Cabinet

L’INSTALLATION.

SECTION 1

 

Préparation du Ventilateur d’évacuation

Solive

1. Sortir le ventilateur de sa boite et confirmer que toutes les

 

pièces sont présentes. En plus du ventilateur d’évacuation

Traverses de Montage

vous devriez avoir:

Figure 3

1

- Grille avec les Lentilles de l’éclairage

2. Installation des Onglets de Montage:à l’aide des guides sur

1

- Ensemble de clapet (attaché)

le châssis du ventilateur, aligner le châssis pour qu’il soit à

2

- Vis #8

effleurement avec le plafond fini. Positionner le ventilateur

2

- Rondelle de Sécurité

pour que les onglets reposent à plat contre la solive et fixer

4

- Traverses de Montage

en place à l’aide de quatre vis ou clous (non-compris)pour

1

- Feuillet d’instructions / sécurité

assurer une bonne installation (Figure 4).

2. Retirer l’ensemble venturi du ventilateur, lequel est fixé en place

 

 

 

 

 

 

par une vis au travers du venturi (Figure 1). C’est une vis

/

"

 

 

 

imperdable et elle demeurera installée dans le venturi. Garder

 

 

 

 

 

 

5 8

 

 

 

l’ensemble venturi et la grille dans la boite jusqu’à ce que vous

 

 

 

 

/

"

 

 

 

 

 

 

1 2

en ayez besoin pour qu’ils ne soient pas endommagés ou perdus.

/

"

 

 

 

 

 

 

3 8

 

 

 

 

/ "

 

1 4

Vis

 

 

Figure 4

 

SECTION 3

Figure 1

Existing Construction

1a. Installation des Traverses de Montage:placer le châssis en

3. Choisir un emplacement pour votre ventilateur. Pour assurer

position entre les solives et tracer un contour sur le matériau

la meilleure performance de l’air et sonore, il est recommandé

du plafond (Figure 5). Mettre le châssis de côté et découper

que la longueur des conduits et que le nombre de coudes

l’ouverture, en prenant soin de ne pas couper ou endommager

soit gardé au minimum, et que des conduits rigides isolés

des câbles électriques dissimulés ou autres utilités. Installer les

soient utilisés. Des plus grands formats de conduits réduiront

traverses sur le châssis et positionner le châssis dans le trou

le bruit et les restrictions au débit d’air. Ce ventilateur

percé précédemment afin qu’il soit à effleurement avec le plafond

nécessite au moins 15,2cm (6po) de dégagement du mur ou

fini. Fixer les extrémités de la traverses à la solive avec des

du plafond et peut s’installer au travers de cloisons sèches

clous ou des vis (non-compris)(Figure 3).

d’épaisseur de 1,9cm (3/4po). Le ventilateur peut être monté

 

directement sur la solive à l’aide des

 

onglets de montage où entre les

 

40,6cm (16po) au centre des solives

 

en utilisant les 4 traverses de

 

montages fournies.

 

4. Sélectionner l’alvéole défonçable la mieux appropriée et l’enlever à l’aide d’un tournevis à lame plate (Figure 2).

SECTION 2

Figure 2

 

Figure 5

 

Nouvelle construction

 

 

 

 

 

1b. Installation des Onglets de montage:positionner le châssis

1. Installation des Traverses de Montage:installer les traverses

 

contre la solive et tracer un contour du châssis sur le matériau

sur le châssis et positionner le châssis près de la solive. En

 

 

du plafond (Figure 6). Mettre le châssis de côté et découper

utilisant le guide sur le châssis du ventilateur, aligner le

 

l’ouverture, en prenant soin de ne pas couper de câble

 

châssis pour qu’il soit à effleurement avec le plafond fini.

 

électrique dissimulé ou autre utilité. Placer le châssis près

Fixer les extrémités des traverses avec des clous ou des vis

 

de la solive et vous assurer qu’il soit à effleurement avec le

(non-comprises)aux solives et glisser le châssis à sa position

 

plafond fini. Fixer avec quatre (4) clous (non-compris)pour

finale (Figure 3).

 

 

assurer une installation adéquate (Figure 4).

 

 

 

 

 

210572063 Rev. A 8-05

www.airkinglimited.com

8 of 12

Figure 6

SECTION 4

Conduits

AVERTISSEMENT: TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.

1.Raccorder le conduit au collet de conduit du ventilateur (Figure 7). Fixer en place à l’aide de ruban ou deserre-joint.Toujours évacuer le ventilateur vers l’extérieur au travers de chapeau mural ou de toit.

Figure 7

REMARQUE: Si le clapet se détache de l’unité, le rattacher en cliquant le collet sur l’unité. Il est conçu pour ne s’assembler que d’une seule manière.

SECTION 5

Câblage

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.

AVERTISSEMENT: TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITES EN CONFORMITÉ AVEC LES CODES ÉLECTRIQUES LOCAUX OU NATIONAUX. SI VOUS N’ÊTES PAS FAMILIER AVEC LES MÉTHODES D’INSTALLATION DE CÂBLAGE ÉLECTRIQUE, RECOURREZ AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ.

1.Câblage du ventilateur/de la lumière sur des circuits indépendants: courir le câblage à partir d’un commutateur mural approuvé et de capacité appropriée. Un fil de neutre (blanc), un fil de mise à la terre (vert ou cuivre nu), et deux fils vivants (le fil noir raccordé à l’interrupteur). Fixer les câbles électriques au châssis à l’aide de connecteur électrique approuvé. Vous assurer que vous laissez suffisamment de câble dans la boîte pour permettre le raccordement au réceptacle du ventilateur.

1a. Par là où vous avez accès à l’intérieur de la boîte de jonction du ventilateur, raccorder un fil Blanc de la maison aux deux fils Blancs du réceptacle de la lumière du ventilateur et le fil Blanc du réceptacle du ventilateur d’évacuation. Raccorder le premier fil Noir provenant du commutateur mural au fil Noir du réceptacle de la lumière. Raccorder le second fil Noir provenant de la maison vers le réceptacle du ventilateur

d’évacuation. Raccorder le fil de mise à la terre de la maison au fil Vert de la vis de mise à la terre du ventilateur (Figure 8). Utiliser des méthodes de raccordement approuvées pour toutes les connexions.

Alimentation provenant dela résidence

Fil de Masse

Blanc

 

Figure 8

Fil Chaud (Noir)

2.Câblage du ventilateur/de la lumière sur le même circuit: courir le câblage d’un commutateur mural approuvé et de capacité appropriée. Un neutre (blanc), un de mise à la terre (vert ou cuivre nu), et un vivant (fil noir raccordé à l’interrupteur mural). Fixer les câbles électriques au châssis avec un connecteur électrique approuvé. Vous assurer de laisser suffisamment de câble dans la boîte pour faire le raccordement au réceptacle du ventilateur.

2a. Par là où vous avez accès à l’intérieur de la boîte de jonction du ventilateur, raccorder un fil Blanc provenant de la maison aux deux fils Blancs du réceptacle de la lumière et le fil Blanc du réceptacle du ventilateur d’évacuation. Raccorder le fil Noir provenant du commutateur mural aux deux fils Noir du réceptacle de la lumière et au fil Noir du réceptacle du ventilateur d’évacuation. Raccorder le fil de mise à la terre de la maison au fil Vert de la vis de mise à la terre du ventilateur (Figure 9). Utiliser des méthodes de raccordement approuvées pour toutes les connexions.

Alimentation provenant dela

résidence

Fil de Masse

Blanc

 

Figure 9

Fil Chaud (Noir)

 

SECTION 6

Compléter l’installation

1.Réinstaller le venturi du ventilateur en le tenant à un angle d’environ 45 degrés, accrocher les deux onglets sur le venturi dans les fentes sur le cabinet et fixer en place en serrant les vis du venturi. Faire tourner la roue de la soufflante à la main pour s’assurer qu’elle tourne librement. Maintenant, connecter le moteur du ventilateur dans le réceptacle (Figure 10).

Figure 10

210572063 Rev. A 8-05

www.airkinglimited.com

9 of 12

2.Enlever les lentilles de verre de la grille en dévissant le bouton au haut des lentilles (Figure 11).

Lentilles de Verre

 

Figure 11

Bouton

 

3.Connecter le cordon des socles de lampe dans le réceptacle approprié (Figure 12).

 

Cordon

 

Support de

Figure 12

la Lumière

4.Aligner les fentes dans la grille avec les crans à l’intérieur du châssis. Insérer les vis # 8 incluses au travers des fentes de la grille dans les crans du châssis. Serrer les deux vis jusqu’à ce que la grille s’ajuste fermement au plafond. NE PAS SERRER A OUTRANCE (Figure 13).

 

Crans

 

Grille

Figure 13

Vis #8

AVERTISSEMENT: UN MANQUEMENT A BIEN SERRER LES VIS DU REFLECTEUR PEUT RESULTER EN UN BRUIT DE CRECELLEMENT OU DE GRONDEMENT.

5.Installer 2 ampoules incandescentes à culot moyen de type A19 de 60 watts au maximum (non-comprises).

6.Réinstaller en place les lentilles en verre en glissant le trou dans les lentilles sur la tige de la grille et en serrant en place avec le bouton des lentilles (Figure 14).

Grille

Barre

Lentilles de

Verre

Trou

Bouton

Figure 14

 

7. Restaurer l’alimentation et tester votre installation.

SECTION 7

Utilisation et entretien

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.

1.Nettoyage de la grille: vous référer à la Section 6Compléter l’installation, pour enlever la grille et les lentilles en verre. Utiliser un détergent doux, tel que du liquide pour la vaisselle, puis sécher à l’aide d’un chiffon doux. NE JAMAIS UTILISER D’ABRASIF OU DE POUDRE A RECURER. Sécher complètement toutes les pièces avant de réinstaller. Vous référer à la Section 6Compléter l’installation, pour réinstaller la grille les lentilles en verre.

2.Nettoyage de l’assemblage du ventilateur: débrancher le cordon d’alimentation du moteur et de la lumière des réceptacles et desserrer la vis du venturi pour enlever le venturi de l’unité. Nettoyer toutes les pièces avec un chiffon sec ou passer délicatement l’aspirateur. NE JAMAIS IMMERGER DES PIÈCES ÉLECTRIQUES DANS L’EAU. Vous référer aux instructions d’installation à la Section 6Compléter l’installation pour réinstaller le venturi.

AVERTISSEMENT: PERMETTRE À L’AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER.

3.Remplacement de l’ampoule: déconnecter l’alimentation de l’unité. Enlever les lentilles en verre de la grille en dévissant le bouton au haut des lentilles(Figure 11). Remplacer l’ampoule (les ampoules) avec une (des) ampoule(s) incandescente(s) à culot moyen de type A19 de 60 watts au maximum. Réinstaller en place les lentilles en verre en glissant le trou dans les lentilles dans la tige de la grille et en serrant en place avec le bouton des lentilles (Figure 14).

210572063 Rev. A 8-05

www.airkinglimited.com

10 of 12