IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

Models:

Exhaust Fan with Light

AK100L, AK100FL

 

 

 

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

1.Read all instructions before installing or using exhaust fan.

2.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

3.Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-relatedconstruction.

5.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.

CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Ducted fans must always be vented to the outdoors.

8.This unit must be grounded.

9.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANYSOLID-STATESPEED CONTROL DEVICE.

10.Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit.

11.NEVER place a switch where it can be reached from a tub or shower.

WARNING: DO NOT USE IN KITCHENS

SAVE THESE INSTRUCTIONS

210952012 Rev. B 8-06

www.airkinglimited.com

1 of 12

INSTALLATION INSTRUCTIONS

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have:

1 - Grill

1 - Damper Assembly (attached)

4 - Mounting Rails

1 - Instruction/Safety Sheet

2.Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The

fan mounts between 16" or 24" on center joists using the 4 provided mounting rails.

3.Select the most convenient electrical knockout and remove using a straight-bladescrew driver

(Figure 1).

SECTION 2

Figure 1

New Construction

 

1.Install the side mounting rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the mounting rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 2).

Housing

 

 

Joist

Figure 2

Mounting Rail

 

SECTION 3

Existing Construction

1.Set housing in position between the joist and trace an outline onto the ceiling material (Figure 3). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the side mounting rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the mounting rails to the joists(Figure 2).

Joist

Figure 3

SECTION 4

Ducting

CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES.

1.Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.

Ducting

Duct

Collar

Figure 4

SECTION 5

Wiring

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

NOTE: This unit includes a side access panel for wiring that does not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective.

1a. External Wire Compartment: Remove the wire compartment cover screw and place cover in a secure place(Figure 5).

Screw

Wire

Compartment

Cover

Figure 5

210952012 Rev. B 8-06

www.airkinglimited.com

2 of 12

1b. Internal Wire Compartment: Remove screw holding blower assembly (venturi) in place and lift assembly out of housing(Figure 6). Remove the wire compartment cover screw and place the cover in a secure place(Figure 7).

Plug

Venturi Screws

Figure 6

NOTE: If the fan motor plug

 

 

 

 

 

Screw

 

 

Wire

 

 

is connected to the fan

 

 

housing receptacle, unplug

 

 

 

Compartment

so the blower assembly can

 

 

 

 

Cover

be completely removed.

 

 

 

 

 

 

 

 

 

 

Figure 7

2.Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and three hot (black, red, yellow leads connected to the switch, one for each function). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.

NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection. Only pull the loose wires outside of compartment. Additional wires will be present.

4.Carefully tuck wires back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier.

SECTION 6

Completing the Installation

1.If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in

Step 1b in Section 5 Wiring.

2.Plug the fan’s quick connect motor cord into the receptacle. This cord will only fit one way into the receptacle (Figure 9).

Figure 9

3.Install the appropriate bulbs (not included) specific to your model (Figure 10):

3. From where you have chosen to access the fan’s junction

AK100L: 100 watt maximum, type A19 medium base

incandescent bulb (not included) and a 7 watt maximum

box, connect the white wire from the house to the two white

type C7 (candelabra base) night light (not included).

wires from the fan. Connect one hot (black) wire from the wall

switch to the black wire from the fan (this is the fan control).

AK100FL: 26 watt maximum, 2 pin quad, fluorescent lamp

Connect second hot (red) wire from the wall switch to the red

(not included) and a 7 watt maximum type C7 (candelabra

wire from the fan (this is the night light control). Connect the

base) night light (not included).

third hot (yellow) wire from the wall switch to the yellow wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the fan (this is the main light control). Connect the ground

 

 

 

 

 

 

 

Night Light

wire from the house to the green wire from the fan (Figure 8).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use approved methods for all connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply from

 

 

 

house

 

 

 

White

 

Figure 10

Lamp Holder

Hot

Hot

 

(Black)

4. Install the grill by squeezing the two ends of the springs

(Red)

 

Ground

 

together and installing them up into the slots on the fan’s

 

 

housing. Push the grill up into position (Figure 11).

 

Hot (Yellow)

 

Figure 8

 

 

 

210952012 Rev. B 8-06

 

www.airkinglimited.com

3 of 12

Figure 11

5. Restore power and test your installation.

SECTION 7

Use and Care

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.

1.Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions inSection 6 Finishing the Installation, to reinstall grill.

2.Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.

CAUTION: ALLOW BULBS TO COOL BEFORE REPLACING.

3.Changing the Light Bulb: Disconnect power to the unit. Remove grill by pulling downward on grill and squeezing grill springs together to release from housing (Figure 12).

Incandescent Bulb (AK100L): Unscrew bulb from lamp holder and replace with a 100 watt maximum, type A19 medium base incandescent bulb.

Fluorescent Bulb (AK100FL): Remove lamp by gently rocking lamp back and forth while applying outward pressure to release the lamp from the base. Replace with a 26 watt maximum, 2 pin quad, fluorescent lamp.

Night Light (AK100L, AK100FL): Unscrew night light bulb from socket and replace with a 7 watt maximum type C7 (candelabra base) night light bulb.

Refer to instructions in Section 6 Finishing the Installation, to reinstall grill.

Figure 12

Troubleshooting Guide

 

Trouble

 

Probable Cause

 

Suggested Remedy

1.

Fan does not operate when the switch is on.

1a.

A fuse may be blown or a circuit tripped.

1a.

Replace fuse or reset circuit breaker.

 

 

1b.

Connector plug from motor is not plugged in.

1b.

Turn off power to unit. Remove Grill and plug motor into receptacle

 

 

 

 

 

in housing. Restore power to unit.

 

 

1c.

Wiring is not connected properly.

1c.

Turn off power to unit. Check that all wires are connected.

2.

Fan is operating, but air moves slower than normal.

2.

Obstruction in the exhaust ducting.

2. Check for any obstructions in the ducting. The most common are bird nests

 

 

 

 

 

in the roof cap or wall cap where the fan exhausts to the outside.

3.

Fan is operating louder than normal.

3a.

Motor is loose.

3a.

Turn off power to unit. Remove grill and check that all screws are fully

 

 

 

 

 

tightened. Restore power to unit.

 

 

3b.

Fan blade is hitting housing of unit.

3b.

Call your dealer for service.

 

 

 

 

 

 

210952012 Rev. B 8-06

www.airkinglimited.com

4 of 12

LIMITED WARRANTY

All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material.

This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty installation, or improper maintenance will not be covered by this warranty.

In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.

Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

FOR PARTS OR TECHNICAL ASSISTANCE

Please call: 1-800-465-7300, MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.

PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.

Reference the type and style of product (located on label inside of the product) when you call. For more information please visit our website: wwwairkinglimited.com

Installer: _________________________________________________________

Installation Date:_________________________________________

Place of Purchase: _________________________________________________

Model Number: __________________________________________

210952012 Rev. B 8-06

www.airkinglimited.com

5 of 12

REPLACEMENT PARTS DIAGRAM

 

5

2

6

 

3

1

 

4

 

9

2

7

 

 

10

14

27

26

11

25

8

15

12

 

24

 

 

13

23

19

16

 

 

17

18

 

20

*

29

22

 

21

28

30

#

Qty.

Description

Replacement Part #

1

1

Fan Housing

5S1202008

2

4

Mounting Rails

5S1299002

3

1

External Wire Cover

5S1202007

4

1

Screw

5S1999010

5

1

Collar

5S1299003

6

1

Damper

5S1299004

7

1

Polarized Receptacle

5S1999001

8

1

Screw

5S1999010

9

1

Motor

5S1202009

10

4

Screw

5S1202010

11

1

Motor Plate

5S1202011

12

2

Hex Nut

5S1202012

13

1

Blower Wheel

5S1202013

14

1

Venturi

5S1202014

15

1

Screw

5S1999011

16

1

Light Reflector - AK100L

5S1202015

 

1

Light Reflector - AK100FL

5S1202023

#

Qty.

Description

Replacement Part #

17

1

Lamp Harness - AK100L

5S1202016

 

1

Lamp Harness - AK100FL

5S1202024

18

1

Clip

5S1202017

19

1

Bushing

5S1202018

20

2

Screw

5S1202019

21

1

Glass Lens

5S5202001

22

1

Grill

5S1202020

23

4

Lens Clip

5S1202021

24

2

Grill Spring

5S1202006

25

1

14 ga Ground Wire

5S1999003

26

1

#10 Ground Screw

5S1999002

27

1

Wire Cover & Light Harness

5S1202022

28

1

FL Lamp Holder - AK100FL*

5S1202025

29

1

Ballast - AK100FL*

5S1202026

30

2

Screw - AK100FL*

5S1202027

 

 

 

 

 

 

 

 

* AK100FL only

210952012 Rev. B 8-06

www.airkinglimited.com

6 of 12

INSTRUCTIONS IMPORTANTES –

MANUEL D’OPÉRATION

Modéles:

Ventilateur combiner, comprend

AK100L, AK100FL

lumière et ventilation

LIRE ET CONSERVER CES INSTRUCTIONS

LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊMEET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À LA PROPRIÉTÉ.

CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.

INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ

Lors de l’utilisation d’appareils électriques, des précautions de base doivent toujours être suivies pour réduire les risques d’incendie, de choc électrique et de blessures corporelles, incluant ce qui suit:

1.Bien lire toutes les instructions avant d’installer ou d’utiliser le ventilateur d’évacuation.

2.Utiliser cette unité seulement de la manière pour laquelle le fabricant l’a conçu. Si vous aviez des questions, veuillez contacter le fabricant.

3.Avant d’effectuer un service ou de nettoyer l’unité, couper l’alimentation électrique dans le panneau de distribution et verrouiller le dispositif de déconnexion afin d’éviter que l’alimentation ne revienne accidentellement. Lorsque le dispositif ne peut être verrouillé, fixer solidement un avis d’avertissement, tel qu’une étiquette, au panneau de distribution.

4.Le travail d’installation et le câblage électrique doivent être effectués par une(des) personne(s) qualifiée(s) en conformité avec tous les codes et normes applicables, incluant la construction relative aux incendies.

5.De l’air en quantité suffisante est requis pour la bonne combustion et l’évacuation de gaz par le conduit (cheminée) provenant d’équipement de brûlage au combustible pour prévenir un refoulement. Suivre les directives du fabricant de l’équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association (NFPA) et de la American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), et de celles des autorités locales du code.

AVERTISSEMENT: POUR USAGE DE VENTILATION GÉNÉRALE EXCLUSIVEMENT. NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES.

6.Lors de coupe ou de perçage des murs et plafonds, ne pas endommager le filage électrique et autres utilités cachées.

7.Les ventilateurs avec conduits doivent toujours être évacués vers l’extérieur.

8.Cette unité doit être mise à la terre.

9.Pour éviter des dommages aux roulements des moteurs et/ou des hélices bruyantes ou déséquilibrées, empêcher la poussière de cloison sèche, poussière de construction, etc., d’atteindre l’unité de puissance.

AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE CHOC ÉLECTRIQUE, NE PAS UTILISER CE VENTILATEUR AVEC UN RÉGULATEUR DE VITESSE ÉLECTRONIQUE.

10.Acceptable pour utilisation au-dessusd’une baignoire ou d’une douche lorsque installé dans un circuit protégé par un disjoncteur de fuite de terre.

11.NE JAMAIS placer un interrupteur à un endroit qui puisse être atteint de la baignoire ou de la douche.

AVERTISSEMENT: NE PAS UTILISER DANS LES CUISINES

CONSERVER CES INSTRUCTIONS

210952012 Rev. B 8-06

www.airkinglimited.com

7 of 12

INSTRUCTIONS D’INSTALLATION

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.

SECTION 1

Préparation du Ventilateur d’évacuation

1.Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir:

1 - Grille

1 - Ensemble de clapet (attaché)

4 - Traverses de Montage

1 - Feuillet d’instructions / sécurité

2.Choisir un emplacement pour votre ventilateur. Pour assurer la meilleure performance du débit d’air et sonore, il est recommandé que la longueur des conduits et que le nombre de coudes soient gardés au minimum et que des conduits rigides isolés soient utilisés. Ce ventilateur nécessitera au moins 20,3cm (8po) de dégagement dans le plafond ou le mur, et s’installe au travers de cloison sèche d’une épaisseur de jusqu’à 1,9cm (3/4po). Le

ventilateur s’installe entre 40,6cm ou 61cm (16po ou 24po) au centre des solives à l’aide des quatre (4) traverses de montage incluses.

3.Sélectionner l’alvéole défonçable la mieux appropriée et l’enlever à l’aide d’un tournevis à lame plate (Figure 1).

SECTION 2

Figure 1

 

Nouvelle Construction

 

1.Installer les traverses sur le châssis et positionner le châssis près de la solive. Aligner le châssis pour qu’il soit à effleurement avec le plafond fini. Fixer les extrémités des traverses avec des clous ou des vis (non-comprises)aux solives et glisser le châssis à sa position finale(Figure 2).

Châssis

 

 

Solive

Figure 2

Traverses de Montage

 

SECTION 3

Construction Existante

1.Placer le châssis en position entre les solives et tracer un contour sur le matériau du plafond (Figure 3). Mettre le châssis de côté et découper l’ouverture, en prenant soin de ne pas couper ou endommager des câbles électriques

dissimulés ou autres utilités. Installer les traverses sur le châssis et positionner le châssis dans le trou percé précédemment afin qu’il soit à effleurement avec le plafond fini. Fixer les extrémités des traverses aux solives (Figure 2).

Solive

Figure 3

SECTION 4

Conduits

AVERTISSEMENT: TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.

1.Raccorder le conduit au collet de conduit du ventilateur (Figure 4). Fixer en place à l’aide de ruban ou deserre-joint.Toujours évacuer le ventilateur vers l’extérieur au travers de chapeau mural ou de toit.

Conduits

Collet du

Conduit

Figure 4

SECTION 5

Câblage

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.

AVERTISSEMENT: TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITES EN CONFORMITÉ AVEC LES CODES ÉLECTRIQUES LOCAUX OU NATIONAUX. SI VOUS N’ÊTES PAS FAMILIER AVEC LES MÉTHODES D’INSTALLATION DE CÂBLAGE ÉLECTRIQUE, RECOURREZ AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ.

REMARQUE: cette unité possède un panneau d’accès latéral pour le câblage qui ne requiert pas l’enlèvement de l’assemblage de la soufflante du ventilateur. Si vous choisissez de raccorder l’unité par l’intérieur, vous aurez besoin d’enlever l’assemblage de la soufflante et le compartiment de câblage intérieur. Les deux méthodes sont également efficaces.

1a. Compartiment de Câblage Extérieur :enlever la vis du couvercle du compartiment à câblage et mettre ce couvercle dans un endroit fiable (Figure 5).

210952012 Rev. B 8-06

www.airkinglimited.com

8 of 12

Vis

Couvercle du

Compartiment

de Câblage

Figure 5

1b. Compartiment de câblage interne:enlever la vis retenant l’assemblage de la soufflante (venturi) en place et soulever l’assemblage hors du châssis (Figure 6).Enlever la vis du couvercle du compartiment à câblage et mettre le couvercle dans un endroit sécuritaire

Raccord

Venturi

 

Vis

Figure 6

 

 

REMARQUE: si le raccord

Vis

Couvercle du

du moteur de ventilateur est

 

Compartiment

raccordé au réceptacle du

 

 

de Câblage

châssis, le débrancher afin

 

 

 

que l’assemblage de la

 

 

soufflante soit

 

 

complètement enlevé.

 

 

Figure 7

2.Courir le câblage à partir d’un commutateur mural approuvé et de capacité appropriée. Un fil de neutre (blanc), un fil de mise à la terre (vert ou cuivre nu), et trois fils vivants (les fils noir, rouge et jaune raccordés à l’interrupteur, un pour chaque fonction). Fixer les câbles électriques au châssis à l’aide de connecteur électrique approuvé. Vous assurer que vous laissez suffisamment de câble dans la boîte pour permettre le raccordement au réceptacle du ventilateur.

3.Par là où vous avez choisi d’accéder à la boîte de jonction du ventilateur, raccorder un fil blanc de la maison aux deux fils blancs du ventilateur. Raccorder un fil vivant (noir) du commutateur mural au fil noir du ventilateur (celui-ciest pour le contrôle du ventilateur). Raccorder le second fil vivant (rouge) du commutateur mural au fil rouge du ventilateur(celui-cipour le contrôle de la lumière de nuit). Raccorder un troisième fil vivant (jaune) du commutateur mural au fil jaune du ventilateur(celui-ciest pour le contrôle de la lumière principale). Raccorder le fil de mise à la terre de la maison au fil vert du ventilateur(Figure 8). Utiliser des méthodes de raccordement approuvées pour toutes les connexions.

 

Alimentation provenant

 

 

de la résidence

 

 

Blanc

Fil

 

 

 

Fil

 

 

Chaud

 

 

(Noir)

Chaud

Fil de

 

 

(Rouge)

Masse

 

Fil Chaud (Jaune)

Figure 8

 

 

 

REMARQUE: les fils du réceptacle du ventilateur pourraient nécessiter d’être tirés à l’extérieur du compartiment pour le raccordement. Tirer uniquement les trois fils lâches à l’extérieur du compartiment. Des fils additionnels y sont présents.

4.Regrouper soigneusement les fils à l’intérieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlevée précédemment.

SECTION 6

Complétion de l’installation

1.Si l’assemblage de la soufflante du ventilateur a été enlevé durant le processus de raccordement, réinstaller la soufflante en inversant les instructions à l’étape 1b de laSection 5 Câblage.

2.Brancher le cordon à raccordement rapide dans le réceptacle. Ce cordon ne s’ajuste que d’une seule façon dans le réceptacle (Figure 9).

Figure 9

3.Installer les ampoules appropriées (non-comprises)spécifiques à votre modèle:

AK100L: Installer une ampoule incandescente à culot moyen de type A19(non-comprise)et une ampoule d’un maximum de 7 watts de type C7 (culot de type candélabre), la lampe de nuit(non-comprise).

AK100FL: Installer une ampoule fluorescente d’un maximum de 26 watts, quad à 2 tiges(non-comprise)et une ampoule incandescente d’un maximum de 7 watts de type C7 (culot de type candélabre), la lampe de nuit(non-comprise).

210952012 Rev. B 8-06

www.airkinglimited.com

9 of 12

Lumière de Nuit

Socle de Lampe

Figure 10

4.Installer la grille en pressant ensemble les deux extrémités des ressorts et en les installant dans les fentes du châssis du ventilateur. Pousser la grille en position (Figure 11).

Figure 11

5. Restaurer l’alimentation et tester votre installation.

SECTION 7

Utilisation et entretien

AVERTISSEMENT:VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.

1.Nettoyage de la grille: Retirer la grille et utiliser un détergent doux, tel que du liquide pour la vaisselle, puis sécher à l’aide d’un chiffon doux. NE JAMAIS UTILISER D’ABRASIF OU DE POUDRE À RÉCURER. Sécher complètement la grille avant de la réinstaller. Pour réinstaller la grille, vous référer à la

Section 6 - Complétion de l’installation.

2.Nettoyage de l’assemblage du ventilateur: nettoyer toutes les pièces avec un chiffon sec ou passer délicatement l’aspirateur dans le ventilateur. NE JAMAIS IMMERGER DES PIÈCES ÉLECTRIQUES DANS L’EAU.

AVERTISSEMENT: PERMETTRE À L’AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER.

3.Remplacement de l’ampoule: débrancher l’alimentation de l’unité. Enlever la grille en la tirant vers le bas et en pressant ensemble les ressorts de la grille pour dégager le bâti (Figure 12).

Ampoule Incandescente (AK100L): Dévisser l’ampoule du socle et la remplacer avec une ampoule incandescente d’un maximum de 100 watts, de type A19 à culot moyen.

Ampoule Fluorescente (AK100FL): Enlever l’ampoule en balançant vers l’avant et l’arrière tout en appliquant une pression externe pour dégager l’ampoule du socle.

Remplacer l’ampoule avec une ampoule fluorescente d’un maximum de 26 watts, quad à 2 tiges.

Lumière de Nuit (AK100L, AK100FL): Dévisser l’ampoule de lumière de nuit de son socle et la remplacer avec une ampoule de lumière de nuit de type C7 d’un maximum de 7 watts (culot de type candélabre).

Référez-vousà laSection 6 Terminer l’installation, pour réinstaller la grille.

Figure 12

Guide de dépannage

Trouble

 

Cause Possible

 

 

Solution Suggérée

1. Le ventilateur ne fonctionne pas lorsque

1a.

Un fusible peut être grillé ou un disjoncteur

 

1a.

Remplacer le fusible ou réinitialiser le disjoncteur.

l’interrupteur est à la position en marche.

 

peut être décle.nché.

 

 

 

 

1b.

La fiche de raccord du moteur n’est

 

1b.

Couper l’alimentation à l’unité. Retirer la grille et brancher le moteur dans

 

 

pas connectée.

 

 

le réceptacle dans le cabinet. Remettre l’alimentation sur l’unité.

 

1c.

Le câblage n’est pas raccordé correctement.

 

1c.

Couper l’alimentation de l’unité. Vérifier que tous les fils sont raccordés.

 

1d.

La moteur est terminee

 

1d.

Remplacez la moteur

2. Le ventilateur fonctionne, mais l’air circule

2.

Obstruction dans les conduits d’évacuation.

 

2.

Vérifier pour toute obstruction dans les conduits. Les plus courantes sont

plus lentement que la normale.

 

 

 

 

des nids d’oiseau dans le chapeau de toit ou mural là où le ventilateur

 

 

 

 

 

s’évacue vers l’extérieur.

3. Le ventilateur fonctionne de manière plus

3a.

Le moteur est lâche.

 

3a.

Couper l’alimentation à l’unité. Retirer la grille et vérifier que toutes les

bruyante que la normale.

 

 

 

 

vis sont complètement serrées. Remettre l’alimentation sur l’unité.

 

3b.

L’hélice du ventilateur frotte contre le cabinet de l’unité.

 

3b.

Appeler votre marchand pour un service.

210952012 Rev. B 8-06

 

www.airkinglimited.com

 

10 of 12