Air King 3C614C User Manual

MODELO 3C614C/9166C
MÉTODO B (POR ADENTRO DE LAS MOLDURAS)
1.Marque la posición de los agujeros para los Tornillos en los bordes interiores del marco de la ventana utilizando el Patrón suministrado. (Figura 2)
2.Instale los 4 Tornillos en el marco. NO LOS APRIETE DEL TODO. Deje 1/8" (3,2 mm) entre la superficie del marco y la Cabeza de los Tornillos.
3.Aflojelos4TornillosparaPaneles de Extensión (Figura 1) y extienda los Paneles Laterales hasta que el Ventilador quede bien ajustado entre los lados del marco de la ventana.
1/8" (3,2 mm) |
PLANTILLA |
Figura 2 |
|
|
| 10 | 11 |
|
|
|
|
|
| |
|
| 8 | 9 |
|
|
|
| 5 | 33 |
|
|
| 3 |
| 26 | 10 | |
|
|
| |||
| 4 |
| 10 |
|
|
|
|
|
|
| |
|
|
| 6 |
|
|
|
|
| 7 |
|
|
36 |
|
|
| 33 |
|
|
|
|
|
| |
2 |
|
|
|
|
|
1 |
|
| 35 |
|
|
|
| 34 |
|
| |
|
|
|
|
| |
|
| 36 | 36 |
|
|
|
|
|
|
| |
LISTA DE PIEZAS DE REPUESTO |
|
| |||
No. | Parte No. | Descripción | Cant. | ||
1 | 2070024G | Emblema AirKing | 1 |
| |
2 | 2010208 | Protector del Ornamento | 1 |
| |
3 | 2096151 | Rejilla Interior | 1 |
| |
4 | 2091121 | Tornillo Prisionero | 1 |
| |
5 | 2011219 | Hélice |
| 1 |
|
6 | 2030073A | Conjunto del Motor | 1 |
| |
7 | 3091118 | Arandela #8 | 8 |
| |
8 | 2091413 | Tornillo para Madera #8 x 3/4" | 4 |
| |
9 | 2060085 | Paneles Laterales | 2 |
| |
10 | 2090039 | Tornillo #8 x 3/8" (Tipo 25) | 4 |
| |
11 | 2010720 | Cuerpo del Ventilador con Canales | 1 |
| |
12 | 2011224 | Rejilla Exterior | 1 |
| |
13 | 2090548 | Atadura para Cable #10 | 1 |
| |
14 | 3091135 | Tornillo #10 x 1/2" | 1 |
| |
15 | 2090289 | Capacitor |
| 1 |
|
16 | 2011225 | Cubierta del Motor | 1 |
| |
17 | 2090008 | Tornillo #8 x 1/2" (Tipo 25) | 5 |
| |
18 | 3091815 | Conector Eléctrico | 4 |
|
Rev. D 1/00
4.Instale el Ventilador en la ventana enganchando las Ranuras en los Tornillos en el marco de la ventana. Deslice el Ventilador hacia abajo en los Tornillos hasta que descanse sobre la parte inferior del marco. (Figura 3)
5.Apriete los Tornillos para Paneles de Extensiónparaasegurarioenesaposición.
Tornillo |
Ranura |
Figura 3 |
OPERACIÓN
Este Ventilador AirKing para Toda la Casa tiene un duradero motor eléctrico reversible de 3 velocidades con arranque por capacitor. Tiene tres velocidades: Alta (Hi), Media (Medium) y Baja (Low) tanto para uso de Ventilador como de extactor. El interuptor de control está convenientemente ubicado en la parte inferior derecha del cuerpo del
Ventilador. Ajuste la Perilla a la dirección y Velocidad deseadas.
| 12 | 14 | 15 | 16 | 17 |
|
|
|
|
|
|
| |
| 13 |
|
|
|
|
|
22 |
|
|
|
|
|
|
23 |
|
|
|
| 18 |
|
|
|
|
|
| 17 | |
|
|
|
|
|
| |
|
|
|
| 19 |
|
|
|
|
| 7 |
|
|
|
|
|
|
|
| 20 |
|
|
|
|
| 22 | 21 |
|
| 24 |
| 23 |
|
| |
|
|
|
|
| ||
| 25 |
|
|
|
| |
| 26 | 29 |
|
|
|
|
| 18 |
|
|
|
| |
10 | 27 | 30 |
|
|
|
|
|
|
| 9 | 8 | ||
| 28 |
|
|
|
| |
32 |
|
|
|
|
|
31
| No. | Parte No. | Descripción | Cant. |
| 19 | 7092211 | Tuerca Hexagonal #8 - 32 | 4 |
| 20 | 2010744 | Cubierta del Interruptor | 1 |
| 21 | 2055052 | Interruptor Reversible de 3 Velocidades | 1 |
| 22 | 2091133 | Tuerca Hexagonal 1/4" - 20 | 4 |
| 23 | 2090053 | Arandela de Presión 1/4" | 4 |
| 24 | 2090566 | Atadura para Cables | 2 |
| 25 | 2090044 | Tornillo 6 - 32 x 1/4" | 1 |
| 26 | 2090509 | Canal de Goma | 4 |
| 27 | 3091303W | Buje para el Alambre | 1 |
| 28 | 2050009AW | Cable de Alimentación | 1 |
| 29 | 2046101 | Alambre de Conducir Verde | 1 |
| 30 | 2046922 | Alambre de Conducir Azul | 1 |
| 31 | 2084071 | Plantilla | 1 |
| 32 | 2065228A | Placa del Interruptor | 1 |
| 33 | 2091130 | Tornillo 1/4" - 20 x 1" | 4 |
| 34 | 2010745 | Perilla del Interruptor | 1 |
| 35 | 2090547 | Tuerca de Lámina | 3 |
| 36 | 2090062 | Tornillo #8 x 1/2" (Punta A) | 6 |
4 |
|
| 2085109A |
OPERATING INSTRUCTIONS & PARTS MANUAL
20" WHOLE HOUSE WINDOW FAN
20" (50.8 cm) MODEL 3C614C/9166C
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
The AirKing 20" (50.8 cm) Whole House Window Fan features three intake and three exhaust speeds. Fan will fit windows 27" (68.6 cm) to 38" (96.5 cm) wide x
6.This Fan is intended for general use ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive, chemi-
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE.
MAINTENANCE
SPECIFICATIONS
Motor ....................................... | 120V, 50/60 Hz |
Blade diameter ....................... | 20" (50.8 cm) |
Speeds .................................... | 3 Intake, 3 Exhaust |
Control .................................... | Rotary Switch |
Approvals ................................ | UL Listed. Close mesh Fan guard |
| meets OSHA requirements. |
WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as liquid dish washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. which will damage the Fan.
Dry all parts with a soft cloth completely before reconnecting to power supply.
STORAGE: When not in use, keep unit in a clean dry place.
|
| MODEL | 3C614C/9166C |
| MOTOR IS PERMANENTLY LUBRICATED. |
|
| |||||
|
| SPEED | HIGH |
| MED | LOW |
| ASSEMBLY AND INSTALLATION | ||||
|
| CFM | 7005 |
| 6165 | 4160 |
| |||||
|
|
|
| PLEASE REMOVE CORRUGATED PACKING RING BETWEEN FAN | ||||||||
|
|
|
|
|
|
|
| |||||
|
| M3/s | 3.31 |
| 2.91 | 1.96 |
| |||||
|
| RPM | 834 |
| 700 | 520 |
| BLADE AND GRILL BEFORE INSTALLATION AND OPERATION OF | ||||
|
|
|
| FAN. |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||
|
| Amps | 3.20 |
| 2.40 | 1.80 |
| The large number of window styles and types makes it impossible to | ||||
|
| Watts | 364 |
| 280 | 185 |
| |||||
|
|
|
| describe one universal installation procedure. |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||
|
| dB A | 64 |
| 59 | 50 |
| The methods outlined below are recommended as being | ||||
|
|
|
|
|
|
|
| most common styles of | ||||
GENERAL SAFETY INFORMATION | choose should allow the window to be closed easily for security and | |||||||||||
protection of home furnishings against the weather. Refer to illustrations | ||||||||||||
1. | Make certain that | the power | source | conforms to the electrical | ||||||||
while following METHOD A (OUTSIDE of TRIM)or METHOD B (INSIDE | ||||||||||||
| requirements of the Fan. |
|
|
| ||||||||
|
|
|
| of TRIM) below. |
|
| ||||||
2. The power cord is equipped with a |
|
| ||||||||||
Tools Required: Screwdrivers |
|
| ||||||||||
| must be inserted into a matching receptacle. Under no circumstances |
|
| |||||||||
| Hardware Provided: Four #8 x 3/4" Slotted Head Screws | |||||||||||
| must the grounding prong be cut off the plug. Where a | |||||||||||
| METHOD A (OUTSIDE OF TRIM) |
|
| |||||||||
| receptacle is encountered, it must be replaced with a properly grounded |
|
| |||||||||
| 1. Loosen 4 Extender Panel Screws and extend Side Panels to clear the | |||||||||||
| Electrical Code (NEC) and all applicable local codes and ordinances. | |||||||||||
|
| outer edge of trim on each side of window. (Figure 1) | ||||||||||
| This work must be done only by a qualified electrician, using copper |
| ||||||||||
|
|
|
|
| ||||||||
| wire only. |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||
WARNING: USE OF A |
|
|
|
| ||||||||
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE |
|
|
|
| ||||||||
THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT |
|
| Extender |
| ||||||||
PERMITTED IN CANADA. |
|
|
|
|
|
| ||||||
|
|
|
| Slots | Panel |
| ||||||
3. Where possible, avoid the use of extension cords. If they must be |
|
| ||||||||||
| Screws |
| ||||||||||
|
|
| ||||||||||
| used, minimize the risk of overheating by ensuring that they are UL |
|
|
| ||||||||
|
|
|
|
| ||||||||
| listed and of the proper gage and length. Never use a single extension |
|
|
|
| |||||||
| cord to operate more than one Fan. |
|
|
|
|
|
| |||||
4. | Do not insert fingers or foreign objects into the Fan. Do not block or |
| Flange |
|
| |||||||
| tamper with the Fan in any manner while it is in operation. Do not touch |
|
| Figure 1 |
| |||||||
| the Fan while in operation or just after it has been turned off, as some |
|
|
| ||||||||
|
|
|
|
| ||||||||
| parts may be hot enough to cause injury. | 2. Rest Fan on window sill with Flange on Side Panels over trim. Push in | ||||||||||
5. | Unplug power cord before installing or servicing the Fan. | |||||||||||
| Side Panels tight against outer edge of trim. With Side Panel in position, | |||||||||||
WARNING: DO NOT DEPEND UPON THE |
| mark Screw locations at top of Slot and drive in the Wood Screws | ||||||||||
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR |
| (provided) until tight. |
|
| ||||||||
SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD. | 3. Retighten Extender Panel Screws to complete installation. | |||||||||||
Rev. D 1/00 |
|
|
| 1 |
|
| 2085109A |

MODEL 3C614C/9166C
METHOD B (INSIDE OF TRIM) |
|
| |
1. Mark Screw locations on inside | 1/8" (3.2 mm) |
|
|
edges of window trim using |
|
| |
|
|
| |
enclosed Template. (Figure 2) |
|
|
|
2. Drive 4 Wood Screws (provided) |
|
|
|
into trim. DO NOT TIGHTEN |
|
|
|
FLUSH. Leave 1/8" space |
|
|
|
between Screw Heads and |
|
|
|
window trim. |
|
|
|
3. Loosen 4 Extender Panel |
|
|
|
Screws (Figure 1) and extend |
|
|
|
Panels on each side of Housing |
|
|
|
until the Fan fits snugly between | Figure 2 |
| |
right and left window trim. |
| ||
|
|
| |
| 10 | 11 |
|
|
|
| |
8 | 9 |
| 23 |
|
| ||
5 | 33 |
|
|
| 26 | 10 | |
3 |
| ||
4 | 10 |
|
|
|
|
| |
| 6 |
|
|
| 7 |
|
|
36 |
| 33 |
|
|
|
| |
2 |
|
|
|
1 | 35 |
|
|
34 |
|
| |
|
|
| |
36 | 36 |
|
|
|
|
|
4. | Mount Fan in window by engaging Slots | Screw |
| with installed Wood Screws on inside | |
| Slot | |
| edge of trim. Lower Fan onto 4 Screws |
|
| until it rests on window sill or sash |
|
| moulding. (Figure 3) |
|
5. | Retighten Extender Panel Screws to |
|
| secure Fan in position. | Figure 3 |
OPERATION
This AirKing Whole House Window Fan is powered by a durable, electrically reversible,
Medium and Low speed settings are available for both INTAKE and EXHAUST mode.) The Control Switch is conveniently located on the lower right hand side of the Fan Body. Adjust Knob direction and Speed desired.
|
| 14 | 15 | 16 | 17 |
|
| 12 |
|
| |||
|
|
|
|
|
| |
| 13 |
|
|
|
|
|
22 |
|
|
|
|
|
|
|
|
|
|
| 18 | 17 |
|
|
|
|
|
| |
|
|
|
| 19 |
|
|
|
|
| 7 |
|
|
|
|
|
|
|
| 20 |
|
|
|
|
| 22 | 21 |
|
| 24 |
| 23 |
|
| |
|
|
|
|
| ||
| 25 |
|
|
|
| |
| 26 | 29 |
|
|
|
|
| 18 |
|
|
|
| |
10 | 27 | 30 |
|
|
|
|
|
|
| 9 | 8 | ||
32 | 28 |
|
|
|
| |
|
|
|
|
|
31
REPLACEMENT PARTS LIST
Key | Part No. | Description | Qty. |
| Key | Part No. | Description |
| Qty. |
1 | 2070024G | Bullseye AirKing | 1 |
| 19 | 7092211 | #8 - 32 Hex Nut |
| 4 |
2 | 2010208 | Guard Ornament | 1 |
| 20 | 2010744 | Switch Cover |
| 1 |
3 | 2096151 | Inside Guard | 1 |
| 21 | 2055052 |
| 1 | |
4 | 2091121 | Set Screw | 1 |
| 22 | 2091133 | 1/4" - 20 Hex Nut |
| 4 |
5 | 2011219 | Blade | 1 |
| 23 | 2090053 | 1/4" Lockwasher |
| 4 |
6 | 2030073A | Motor Assembly | 1 |
| 24 | 2090566 | Wire Tie |
| 2 |
7 | 3091118 | #8 Washer | 8 |
| 25 | 2090044 | 6 - 32 x 1/4" Screw |
| 1 |
8 | 2091413 | #8 x 3/4" Wood Screw | 4 |
| 26 | 2090509 | Rubber Channel |
| 4 |
9 | 2060085 | Side Panels | 2 |
| 27 | 3091303W | Strain Relief |
| 1 |
10 | 2090039 | #8 x 3/8" Screw (Type 25) | 4 |
| 28 | 2050009AW | Cordset |
| 1 |
11 | 2010720 | Fan Body w/Channels | 1 |
| 29 | 2046101 | Lead Wire Green |
| 1 |
12 | 2011224 | Outside Guard | 1 |
| 30 | 2046922 | Lead Wire Blue |
| 1 |
13 | 2090548 | Wire Tie #10 Stud | 1 |
| 31 | 2084071 | Template |
| 1 |
14 | 3091135 | #10 x 1/2" Screw | 1 |
| 32 | 2065228A | Switch Plate |
| 1 |
15 | 2090289 | Capacitor | 1 |
| 33 | 2091130 | 1/4" - 20 x 1" Screw |
| 4 |
16 | 2011225 | Motor Cover | 1 |
| 34 | 2010745 | Switch Knob |
| 1 |
17 | 2090008 | #8 x 1/2" Screw (Type 25) | 5 |
| 35 | 2090547 | Palnut |
| 3 |
18 | 3091815 | Wire Nut | 4 |
| 36 | 2090062 | #8 x 1/2" Screw (A Point) |
| 6 |
Rev. D 1/00 |
|
| 2 |
|
|
| 2085109A |
MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES
20" (50,8) VENTILADOR PARA TODA LA CASA
20" (50,8 cm) MODELO 3C614C/9166C
LEA Y GUARDE ESTAS INSTRUCCIONES
LÉALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR, INSTALAR, OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO. PROTÉJASE A SÍ MISMO Y A LOS DEMÁS OBSERVANDO TODA LA INFORMACIÓN SOBRE SEGURIDAD. ¡NO SEGUIR LAS INSTRUCCIONES PODRÍA RESULTAR EN LESIONES PERSONALES Y/O DAÑOS A LA PROPIEDAD! GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.
DESCRIPCIÓN
El Ventilador AirKing 20" (50,8 cm) para Toda la Casa tiene tres velocidades de ventilación y tres de extracción. El Ventilador puede instalarse en ventanas desde 27" (68,6 cm) hasta 38" (96,5 cm) de ancho por
6.Este ventilador es para uso general EXCLUSIVAMENTE. NO deberá usarse en localidades potencialmente peligrosas tales como atmósferas inflamables, explosivas, cargadas de gases o húmedas.
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGASELÉCTRICAS,NOUSEESTEVENTILADORCONNINGÚN DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO SÓLIDO.
MANTENIMIENTO
ADVERTENCIA: DESCONECTE SIEMPRE EL CORDÓN ANTES DE INTENTAR REALIZAR CUALQUIER FUNCIÓN DE SERVICIO.
ESPECIFICACIONES |
|
| LIMPIEZA: Use un trapo y una solución de jabón suave, tal como | |||||||||
Motor ............................................... 120V, 50/60Hz | detergente líquido para lavar trastes. |
|
| |||||||||
Tarmano De Paletas ...................... 20" (50,8 cm) | ADVERTENCIA: No use gasolina, bencina, diluyente de pintura ni | |||||||||||
Velocidades .................................... 3 de Extracción, 3 de Ventilación | limpiadores fuertes en aerosol, ya que éstos dañarán el Ventilador. | |||||||||||
Control ............................................ Conjuntor rotatorio | ALMACENAMIENTO: Cuando no lo utilice, mantenga el aparato en un | |||||||||||
Aprobaciones .............. Catalogación UL. El protector de malla cerrada | ||||||||||||
lugar limpio y seco. |
|
| ||||||||||
|
| del ventilador satisface las normas OSHA. |
|
| ||||||||
|
| EL MOTOR HA SIDO PERMANENTEMENTE LUBRICADO. | ||||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
| MODELO |
| 3C614C/9166C |
|
| ENSAMBLE Y INSTALACIÓN |
|
| ||||
| VELOC. | ALTA | MEDIA |
| BAJA |
|
|
| ||||
|
|
| POR FAVOR QUITE EL ANILLO CORRUGADO DE EMPAQUE QUE | |||||||||
| CFM |
| 7005 | 6165 |
| 4160 |
| |||||
|
|
|
| ESTÁ ENTRE LA PALETA Y LA REJILLA, ANTES DE HACER LA | ||||||||
|
|
|
|
|
|
|
| |||||
| M3/s |
| 3.31 | 2.91 |
| 1.96 |
| INSTALACIÓN Y PONERLO A FUNCIONAR. |
|
| ||
| RPM |
| 834 | 700 |
| 520 |
| El gran número de estilos y tipo de ventanas hace imposible describir un | ||||
|
|
|
|
|
|
|
| procedimiento de instalación universal. |
|
| ||
| Amps |
| 3.20 | 2.40 |
| 1.80 |
|
|
| |||
| Watts |
| 364 | 280 |
| 185 |
| Los métodos que se detallan a continuación se recomiendan como aptos | ||||
|
|
|
|
|
|
|
| paralamayoriadelasventanasdedospanelesquesedeslizanverticalmente. | ||||
| dB A |
| 64 | 59 |
| 50 |
| |||||
|
|
|
| Cualquiera que sea el método que usted elija, deberá permitir que la | ||||||||
|
|
|
|
|
|
|
| |||||
INFORMACIÓN GENERAL SOBRE SEGURIDAD | ventana se cierre con facilidad para su seguridad y para la protección de | |||||||||||
los enseres domésticos contra el mal tiempo. Consulte las ilustraciones | ||||||||||||
1. Cerciórese de que | la fuente de electricidad se adapte a los | mientras utiliza el MÉTODO A (POR AFUERA DE LAS MOLDURAS)o | ||||||||||
el MÉTODO B (POR ADENTRO DE LAS MOLDURAS)a continuación. | ||||||||||||
requerimientos eléctricos del ventilador. |
|
| ||||||||||
|
| Herramientas Requeridas: Destornillador |
|
| ||||||||
2. El cordón eléctrico está equipado con una clavija a tierra de tres espigas |
|
| ||||||||||
que tiene que ser enchufada a un receptáculo del mismo diseño. Bajo | Elementos Suministrados: Cuatro Tornillos #8 x | 3/4" con Ranura | ||||||||||
ninguna circunstancia deberá cortarse la espiga a tierra de la clavija. De |
| para Destornillador Plano | ||||||||||
existir un receptáculo de pared de dos espigas, deberá reemplazarse | MÉTODO A (POR AFUERA DE LAS MOLDURAS) | |||||||||||
por uno de tres espigas debidamente puesto a tierra e instalado de | ||||||||||||
conformidad con el Código Nacional de Electricidad y todos los códigos | 1. Afloje los 4 Tornillos para Paneles de Extensión y extienda los Paneles | |||||||||||
y ordenanzas locales aplicables. El trabajo deberá hacerlo un electricista |
| Laterales, pero que el Ventilador aún quepa en la ventana. (Figura 1) | ||||||||||
calificado, utilizando exclusivamente alambre de cobre. |
|
|
|
| ||||||||
ADVERTENCIA: NO SE RECOMIENDA EL USO DE UN ADAPTADOR |
|
|
|
| ||||||||
DE TRES A DOS ESPIGAS. LA CONEXIÓN INDEBIDA PODRÍA CREAR |
|
| Tornillo para |
| ||||||||
EL RIESGO DE SER ELECTROCUTADO. EL USO DE TALES |
|
|
| |||||||||
ADAPTADORES NO ESTÁ PERMITIDO EN CANADÁ. |
|
| Paneles de |
| ||||||||
3. Siempre que sea posible, evite el uso de extensiones eléctricas. Si tienen |
| Ranura | Extensión |
| ||||||||
que usarse, minimice el riesgo de sobrecalentamiento asegurándose de |
|
|
|
| ||||||||
que sean de catalogación UL y del calibre y la longitud adecuadas. Nunca |
|
|
|
| ||||||||
use una sola extensión para operar más de un ventilador. |
|
|
|
| ||||||||
4. No introduzca los dedos ni objetos extraños en el ventilador. No |
| Brida |
|
| ||||||||
obstruya ni manipule indebidamente el ventilador mientras esté en |
|
| Figura 1 |
| ||||||||
operación. No toque el ventilador mientras esté en operación ni |
|
|
| |||||||||
|
|
|
| |||||||||
|
|
|
| |||||||||
inmediatamente después de haberlo apagado, ya que ciertas partes | 2. | Coloque el Ventilador en el marco de la ventana con la Brida de los | ||||||||||
podrían estar lo suficientemente calientes como para causar una lesión. |
| Paneles Laterales sobre la moldura de la ventana. Presione los | ||||||||||
5. Desenchufe el cordón eléctrico antes de instalar o dar servicio al |
| Paneles Laterales hasta que queden bien ajustados contra las | ||||||||||
ventilador. |
|
|
|
|
|
| molduras. Con Paneles Laterales en esta posición, marque los | |||||
ADVERTENCIA: NO DEPENDA DEL INTERRUPTOR DE ENCENDIDO |
| agujeros para los Tornillos en la parte superior de las Ranuras, instale | ||||||||||
Y APAGADO COMO EL ÚNICO MEDIO PARA INTERRUMPIR LA |
| 4 Tornillos para Madera (provistos) y apriételos. |
|
| ||||||||
ALIMENTACIÓN ELÉCTRICA CUANDO INSTALE O DÉ SERVICIO AL | 3. | Apriete los Tornillos para Paneles de Extensión para completar la | ||||||||||
VENTILADOR. SIEMPRE DESENCHUFE EL CORDÓN ELÉCTRICO. |
| instalación. |
|
| ||||||||
Rev. D 1/00 |
|
|
| 3 |
|
| 2085109A |