834571 1004 B
JA-2MECD JA-2HCD JA-2MCD
HANDSFREE COLOR VIDEO INTERCOM
JA-2MECD |
JA-2HCD |
Master monitor station(with Picture memory) |
Sub monitor station |
JA-2MCD
Master monitor station
INSTALLATION & OPERATION MANUAL
PRECAUTIONS
General Prohibitions Prohibitions to dismantle the unit Prohibitions to subject the unit to water General Precautions
WARNING
(Negligence could result in death or serious injury to people)
1.High voltage is present internally. Do not open the case. Electric shock could result.
2. Do not dismantle or alter the unit. Fire or electric shock could result.
3.Do not connect the unit with any non-specified power source. Fire or electric shock could result.
4.Keep the unit away from water or any other liquid. Fire or electric shock could result.
5.Do not put any metal into the unit through the openings. Fire, electric shock, or unit trouble could result.
6.When existing chime wires are used, it is possible that they contain AC voltage. Electric shock or unit damage could result. Ask a qualified technician.
CAUTION
(Negligence could result in injury to people or damage to property)
1. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could result.
2. In case of electrical storms, unplug the unit from AC outlet. If not, fire or electric shock could result. (If AC cord is not seen, turn off the Power switch on the left side.)
3.If LCD is punctured, do not allow contact with the liquid crystal inside. Inflammation could result. If necessary, gargle your mouth and clean your eyes or skin with clear water for at least 15 minutes, and consult your doctor.
4.Do not install the unit in any of the following locations.Fire, electric shock,or unit trouble could result.
*Places under direct sunlight, or near heating equipment that varies in temperature.
*Places subject to dust, oil, chemicals,
*Places subject to moisture and humidity extremes, such as bathroom,cellar, greenhouse, etc.
*Places where the temperature is quite low, such as inside a refrigerated areaor in front of air-conditioner.
*Where noise generating devices such as dimmer switches, invertor electrical products.
*Places subject to steam or smoke (near heating or cooking surfaces).
*Where noise generating devices such as dimmer switches, invertor electrical appliances, are closeby.
*Places subject to steam or smoke (near heating or cooking surfaces).
GENERAL PRECAUTIONS
1.The unit is for domestic use only. Do not use outdoors.
2.When power fails, the unit becomes inoperative.
3.The unit is for wall-mount use only. For desktop applications, use desk stand.
4.In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
5.If the phone is operated near OA equipment, Radio or TV, they interactively influence by radio frequency interference. Carefully select both locations for installation and operation.
1 |
PACKAGE CONTENTS |
|
1 |
|
2 |
JA-2MECD |
4 |
|
|
|
3 |
|
|
5 |
|
JA-2MCD |
|
|
JA-2HCD |
|
Package contents
1JA-2MECD, JA-2MCD or JA-2HCD
2Packet of screws
3Optional function connector
4Door release connector
5Mounting bracket
6INSTALLAITON & OPERATION MANUAL
2 INSTALLATION
2-1
[1]
[2]
50mm+
(2")
Installation locations
1.Do not mount the inside monitor station in areas directly facing bright lighting. Viewing image may be affected.
2.On the left side, the monitor station has a POWER switch. Secure a space of 50mm(2") or more between the unit and a wall or furniture.
- 2 -
2-2 |
|
|
|
|
|
|
JA-2MECD |
|
|
|
|
JA-DAC |
JA-2MCD |
JA-2HCD |
JA-2HCD |
||
|
|
|
|
|
|
2 |
4 |
|
|
4 |
|
2 |
|
|
|
B1, B2 |
|
JA-DAC |
B1, B2 |
B1, B2 |
|
B1, B2 |
|
|
|
||||
|
|
|
|
JA-2SD |
JA-2SD |
|
|
|
JA-2HCD |
JA-2HCD |
|
|
JA-2MECD |
4 |
|
|
|
JA-DAC |
JA-2MCD |
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
4 |
JA-2SD |
JA-2SD |
|
B1, B2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
JA-2HCD |
JA-2HCD |
|
|
JA-2MECD |
|
|
|
|
JA-DAC |
JA-2MCD |
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
4 |
|
|
|
4 |
|
JA-2SD |
JA-2SD |
|
B1, B2 |
|
|
|
|
|
|
|
8 |
|
|
|
|
|
|
|
Wiring method
Wire the inside stations in a station-to-station (daisy-chained) manner.
2-3
|
(x2) |
JA-2MECD |
JA-2HCD |
JA-2MCD |
|
A1 |
A1 |
B1 |
B1 |
B1 |
JA-DAC |
A2 |
A2 |
B2 |
B2 |
B2 |
|
A1 |
+ |
+ |
|
|
JA-D |
|
|
|||
A1 |
A2 |
- |
- |
|
|
|
|
||||
|
A2 |
|
|
|
|
120 |
120 |
Cable
1.Use 2-conductor, non-shielded cable. Vinyl-jacketed cable with PE(polyethylene) insulated wires is recommended.
2.Never use loose wires, shielded wire, twisted pairs, or coaxial cable.
3.When using existing cable with multiple wires, terminate both ends of each unused pair with a 120 ohm resistor.
2-4
D1 |
A |
A' |
D2 |
|
|
||
|
|
|
JA-DAC |
|
|
|
JA-D |
|
JA-DAC |
JA-2MECD |
|
E |
|
|
|
M |
JA-2MCD |
|
|
|
C |
IER-2 |
|
|
D |
|
|
|
PS |
|
|
|
PS-2420 |
|
|
|
PS-2410 |
|
|
|
S1 |
|
B |
ADAP |
|
|
|
JAW-AZ |
|
|
|
|
JA-2HCD |
JA-2SD |
|
|
|
|
|
CAM |
|
|
|
|
S2 |
|
|
|
JA-2HCD |
JA-2SD |
|
|
|
|
|
CAM : motion detect sensor or sensor / camera |
|
|
Wiring distance
|
|
0.65mm |
|
22AWG |
|
1.0mm |
18AWG |
A |
|
50m |
|
165' |
|
100m |
330' |
A' |
|
50m |
|
165' |
|
100m |
330' |
B |
|
50m |
|
165' |
|
100m |
330' |
C |
|
5m |
|
16' |
|
10m |
33' |
D |
|
50m |
|
245' |
|
100m |
330' |
E |
|
50m |
|
165' |
|
100m |
330' |
3 |
|
MOUNTING |
|
|
|
||
|
|
|
|
|
|
[3] |
|
|
|
|
|
[1] |
[2] |
|
46mm |
JA-2MECD |
|
|
|
|
(1-13/16") |
||
JA-2MCD |
|
|
|
|
|
||
JA-2HCD |
|
|
|
|
|
||
|
|
|
|
|
|
|
83.5mm |
|
|
|
|
|
|
|
(3-5/16") |
|
1 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9mm |
|
|
|
|
|
|
|
(3/8") |
|
|
|
|
|
|
|
3. |
|
|
|
|
|
|
|
PS-2420 |
|
|
|
PS-2420DIN |
|
|
PS-2420S |
|
|
|
PS-2410DIN |
||
|
PS-2420UL |
[2] |
[3] |
|
[4] |
|
|
|
|
|
|
|
|||
|
|
|
|
83.5mm |
|
|
|
|
|
|
|
(3-5/16") |
|
|
|
Mounting |
|
|
|
|
|
[1]Screw (x4)
[2]Mounting bracket
[3]Two-gang box
• Provide a box DEEP enough to accommodate all cables incl. options. [4] DIN rail
1.Depress UNLOCK button (to unlock or to insert the wire securely).
2.Insert the cable into terminal.
3.When GANG BOX is not provided, the cable can be surface run from the top or bottom of the unit. Cut open the cable inlet hole to run wires to the back of the unit.
- 3 -
4 WIRING |
[1] JA-2MECD |
|
JA-2MCD |
[6] OP
2
|
|
NP |
|
EL-9S |
PT |
[3] |
|
2 |
A1 A2 |
NP |
|
|
EL-9S |
PT |
|
2 |
|
JA-DAC |
NP |
|
|
|
|
[4] |
A1 A2 |
|
2
NP
JA-DAC JA-D
[9] |
JAW-AZ |
|
2 |
||
Motion detect |
||
Camera |
|
NP
Adaptor
JAW-AZ
Motion detect |
2 |
Camera |
|
NP
Adaptor
[7] OP |
IER-2 |
2
1 E
NP
[10] OP
B1 |
SUBMASTER |
OPTION |
L1 |
|
A1 |
L1 |
|||
DOOR-1 |
L2 |
|||
B2 |
|
|
||
|
|
|
L2 |
|
A2 |
|
|
|
|
A1 |
DOOR-2 |
|
|
|
A2 |
|
|
||
|
|
|
||
C1 |
ADAPTER-1 |
|
|
|
C2 |
|
|
|
|
C1 |
ADAPTER-2 |
|
|
|
C2 |
|
DC24V |
||
S |
CALL EXT |
|||
S |
SPEAKER |
+ |
- |
|
|
|
- |
||
4 |
|
|
|
|
[2] |
|
|
2 |
|
+ |
- |
P |
||
|
||||
|
|
JA-2HCD |
||
|
|
[8] |
|
|
|
B1 |
A |
|
|
|
B2 |
|
|
|
|
B1 |
|
|
|
|
B2 |
|
|
-
4
[5]
PS-2420DIN |
|
230V AC |
|
|
N |
|
|
L |
IN 230V~ 50/60Hz NL |
||
|
|
2A - + |
24V DC2A |
- |
|
+ |
|
|
PS-2420 |
|
|
|
+ |
- |
100V-240V~ |
24V DC |
|
50/60Hz |
2A |
|
|
|
|
PS-2410DIN |
230V AC |
|
|
|
N |
|
L |
IN 230V~ 50/60Hz |
NL |
|
1A - + |
- |
|
+ |
|
24V DC1A |
|
DC 24V
-
+
[2] JA-2SD
SUB IN
SUB OUT
ON - OFF
[8]
JA-2MECD JA-2HCD
JA-2SD
ON
RY-3DL |
JA-2MECD |
|
[2] |
+ - |
|
|
L1 |
|
#1 |
|
|
||
b1 |
OG(b1) |
|
|
|
|
|
C1 |
|
|
|
|
||
L1 |
b2 |
YE(b2) |
|
|
|
|
|
b3 |
#2 |
|
|
|
|
L2 |
L |
|
|
|
[2] JA-2SD |
|
RD(L1) |
|
|
JA-2HCD |
|||
L2 |
D1 |
|
|
|||
C2 |
|
BR(L1) |
|
|
|
|
PT |
E |
OG(L2) |
|
|
|
|
D2 |
|
|
[8] |
|
||
|
YE(L2) |
|
|
|
||
|
|
|
|
|
||
|
|
DC24V |
|
|
|
|
|
|
+ |
PS24 |
B1 |
A |
SUB IN |
|
+ |
- |
|
B2 |
|
|
|
- |
|
|
B1 |
|
|
|
|
|
|
|
SUB OUT |
|
|
|
|
|
B2 |
|
|
|
[8] |
ON - OFF |
OG: Orange |
|
|
|
|
|
|
|
YE: Yellow |
- |
JA-2MECD JA-2HCD |
JA-2HCD |
BR: Brown |
|||
RD: Red |
|
JA-2SD |
JA-2SD |
|
|
OFF |
ON |