6000 K, 6010 K, 6040 K,
6050 K, 6051 K
Glaskeramik-Einbau-Kochmulden
Fitted Glass Ceramic Cooking Units
Tables de cuisson vitrocéramiques à encastrer
Piani di cottura componibili in vetroceramica
Glaskeramiek-inbouwkookplaten Inbyggda glaskeramik-kokhällar
Kalusteisiin sijoitettavat keraamiset keittotasot
Einbauund Gebrauchsanweisung
Installation Directives and Instructions for Use
Notice de montage et d’utilisation Istruzioni per il montaggio e per l’uso Inbouwen gebruiksaanwijzing Monteringsoch bruksanvisning Asenusja käyttöohje
Table of Contents |
GB |
Fitting Instructions |
17 |
Illustrations |
17/18 |
Before Fitting |
19 |
Fitting |
19 |
Connection |
19/20 |
Safety Instructions |
21 |
For the Fitter |
21 |
For the User |
21 |
Description of Equipment |
22 |
6000 K, 6010 K, 6040 K, |
22 |
6050 K, 6051 K |
23 |
Glass Ceramics |
24 |
Attributes |
24 |
How to Operate |
25 |
The Switch |
25 |
Table of Settings |
25 |
Residual-Heat Display |
25 |
Dual-Circuit Connection |
26 |
The right Pots and Pans |
26 |
General Remarks |
26 |
Cleaning and Care of Glass Ceramics Surfaces |
27 |
Basic Principles |
27 |
Food that has Spilled Over |
27 |
Burned-in Sugar |
27 |
Melted Plastic |
27 |
Spots and Stains |
28 |
Grains of Sand |
28 |
Worn Décor |
28 |
What to do when ... |
29 |
Faults you can Remedy Yourself |
29 |
After Sales Service |
29 |
16
Fitting Instructions
R 2 |
17
Fitting Instructions
R 3 |
1 = Work Top
2 = Insulation
3 = Placement Area
4 = Tensioning Element
18
Before Fitting
These fitted cooking units are intended for placement in the cutout of a table top (Illustration 3).
The unit must be connected by an authorized electrician, since this ensures that both the statutory regulations and the connection conditions of the local electricity supply company are observed.
Make cutout of 560 mm x 490 mm in the work top with a margin of 55 mm both in front and behind.
The cooking-unit cupboard must have a protective floor that is at least 30 mm from the underside of the unit and can only be removed with the use of tools.
Extractor hoods above the unit must be fitted in accordance with the extractor-hood fitting instructions.
Unit furniture must be treated with a plastic coating or veneer with heat-resistant adhesive (100 C), as it can otherwise deform or loosen, especially at thinner points.
Fitting
The use of massive wooden wall-side skirting boards on the table top behind the fitted unit is permissible provided the minimum clearances have been observed.
Alterations of surface colour can be traced to influence of light.
The fitted cooking unit must be installed such that the control switches are positioned to the right (Illustration 1).
Connection
In cases of electrical connection of the unit, plans must be made for the use of a facility that enables contact separation from the mains supply of at least 3 mm for all pins.
Suitable separators are LS switches, fuses and protective devices.
The mains connection cable must be of type H05VV-F or H05VVH2-F at least.
Mains |
Cable |
Supply Voltage |
230...240 V~ |
3 x 4² |
230...240 V |
400 V 2 N~ |
4 x 2.5² |
230 V |
19