AEG-Electrolux 125D-W User Manual

0 (0)

125 D

ExtractorHood

InstallationandOperatingInstructions

Contents

Introduction

3

Extraction mode

3

 

 

Recirculation mode

4

 

 

Electrical connection for UK

5

Technical details

6

Installation

7

Safety warnings for kitchen unit installer

7

 

 

Wall mounting

9

 

 

Hood operation

11

Safety warnings for user

12

 

 

Maintenance and care

13

Opening the grid

13

 

 

Grease filter

13

 

 

Carbon filter

14

 

 

Changing the light bulb

15

 

 

Cleaning

15

Accessories

16

What to do if

17

Service & Spare Parts

18

Printed on recycled paper.

AEG – putting words into action.

2

AEG-Electrolux 125D-W User Manual

Introduction

Extraction mode

The hood is supplied as an extractor unit and can also be used as a filtered function (recirculation) by fitting activated carbon filters (availableasanaccessory).

The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.

To connect up the hose, you should first fit the bayonet-mounting flange C (Ø 100-120 mm) on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in

Fig. 1).

Close off the unused hole using the bayonet fitting caps D.

 

D

 

A

 

B

1

C

C

A

B

D

● Important! To use the back hole B, remove switch F from the top hole. — Fig 2.

2

3

● Move the lever L to position A — Fig. 3.

L

3

L

When connecting the hood using a telescopic wall pipe, you should use a non-inflammable outlet hose ABS 120 (120 mm Ø)

E-Nr. 942 118 611 from our range of special accessories.

Recirculation mode

The air is filtered and recirculated through the front grid.

Move the lever L to position F — Fig. 3.

You will need an original KFF activated carbon filter. (See accessories).

Summer/Winter Hood Conversion

To avoid excessive heat loss during the winter months, we recommend that the hood be converted from extraction mode to recirculation.

In order to convert the hood, a charcoal filter (available as an accessory) is required. Follow the instructions for operating the hood to recycle air.

When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again to extraction. Please consult the assembly instructions for operating the hood in extraction mode.

4

Electrical connection for the UK

Appliances with 2 wires

WARNING: DOUBLE INSULATED - DO NOT EARTH

The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp.

We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will complywiththeIEEandanylocalregulations.

NOTE:

Theterminology“DOUBLEPOLE”meansthatboththeliveandthe neutralsuppliesareswitchedanddisconnectedatthesametime. The terminations labelled SUPPLY are for the connection for the internalhousewiringandtheterminationslabelledLOADareforthe appliance.

IMPORTANT

The wires of the mains lead supplied with this appliance are coloured in accordance with the following code:

Blue-Neutral

Brown-Live

As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in the plug, proceed as follows: The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

 

BLUE

BROWN

 

(NEUTRAL)

(LIVE)

 

 

L

 

 

LOAD

 

N

L

 

SUPPLY

 

LOAD

FUSE

ON

DP 13A, 250V

 

 

 

N SUPPLY

5

Technical details

Dimensions

Height x Width x Depth (in cm)

69-113 x 59.9 x 51

 

 

 

 

Weight

 

Net:

11,5 kg

Gross:

12,6 kg

 

 

Maximum absorbed power:

205 W

Motor absorption

1 x 125 W

 

 

Lighting:

2 x 40 W

 

 

Length of the cable:

110 cm

 

Fan powers (speed), speed in compliance with DIN 44971

Extraction mode

 

1

115 m3/h

2

152 m3/h

3

210 m3/h

Recirculation mode

 

1

110 m3/h

2

129 m3/h

3

145 m3/h

Flange:100-120 mm Ø

 

 

 