Chapter 2 Installation and Operation

UNPACK, INSPECT, POWER UP

Receiving Inspection

Carefully inspect the MX2800 STS-1for any damage that might have occurred in shipment. If damage is suspected, file a claim immediately with the carrier and contactADTRAN Technical Support (see the front section of this manual for phone numbers). Keep the original shipping container to use for future shipment or verification of damage during shipment.

ADTRAN Shipments Include

The following items are included in shipments of the MX2800

STS-1:

MX2800 STS-1unit

DC or AC power supply (two power supplies come with the Redundant versions)

Controller card (two cards come with the Redundant versions)

8-pinto6-pinmodular cable (Modem version only)

8-pinto8-pinmodular cable

8-pinmodular toDB-9female connector

Two 4-positionterminal lug connectors

3-positionterminal lug connector

61200659L1-1

MX2800 User Manual

2-1

Chapter 2. Installation and Operation

Six-footAC power cord (AC Versions only)

Mounting ears and screws for 19-inchor23-inchrack installation

User Manual or CD containing the User Manual

The ADTRAN MX2800 STS-1MIB is available atwww.adtran.com.

Power Up

The AC version of the MX2800 STS-1is provided with asix-footpower cord, terminated by athree-prongplug which connects to a grounded 120 VAC power receptacle.

Power to the AC version of the MX2800 STS-1must be provided from a grounded 120 VAC, 60 Hz receptacle.

The DC version of the MX2800 STS-1is provided with two4-positionmodular terminal lug connectors. These connectors make it easier to perform initial wiring and to connect and disconnect DC power when replacing rackmount units.

For more detailed information on power connections, refer to

Chapter 8, Power Loss Recovery.

Once the modular connector is wired, push it firmly into one of the rear panel POWER connectors.Figure 2-1 andTable 2-1 on page

2-2

MX2800 User Manual

61200659L1-1

Chapter 2. Installation and Operation

2-3 illustrate the DC power connector and give definitions for the four connector symbols.

The chassis should be connected to an earth ground using the ground stud located between the AC and DC power sources on the rear panel.

N E T

 

PWR

PWR

FAIL

FAIL

PWR

FAIL

Figure 2-1. DC Power Connector

Table 2-1.DC Connector Symbol Definitions

Symbol

Definition

Battery backup connection. If AC fails, a trap is sent to PWR FAIL alert user when connected to the 4175043L2 battery

backup system or equivalent

-Negative side of DC power source (usually -48V)

RET

Positive side of DC power source (usually ground)

Frame Ground

61200659L1-1

MX2800 User Manual

2-3

Chapter 2. Installation and Operation

The following UL requirements must be met during installation of the MX2800 STS-1DC version:

1.Disconnect all power sources prior to servicing (unit may use multiple power sources).

2.Input: Minimum 48 VDC, 0.8 A

Minimum 120 VAC, 0.32 A

3.Connect to a reliably grounded -48VDC source which is electrically isolated from the AC source.

4.The branch circuit overcurrent protection shall be a fuse or circuit breaker rated minimum 48 VDC, maximum 20 A.

5.A readily accessible disconnect device that is suitably approved and rated, shall be incorporated in the field wiring.

6.The chassis should be connected to an earth ground using the ground stud located between the AC and DC power sources on the rear panel.

7.The unit shall be installed in accordance with the requirements of NEC NFPA 70.

8.The unit shall be installed in accordance with Articles 400 and 364.8 of the National Electrical Code NFPA 70 when installed outside of a Restricted Access Location (i.e. Central Office, behind a locked door, or service personnel area only).

9.Care should be taken not to upset the stability of the equipment rack after installation is complete.

To meet the UL requirements during installation, use copper conductors only.

2-4

MX2800 User Manual

61200659L1-1

Chapter 2. Installation and Operation

RACKMOUNT INSTALLATION

The MX2800 STS-1can be mounted into a standard19-inchor23-inchequipment rack. Follow these steps to mount your unit into a rack:

1.Prepare the MX2800 STS-1mounting ears by scraping the paint away from the mounting ears’ portion that makes contact with the rack and the portion where the screw mounts into the side of the MX2800STS-1.

2.Install the mounting flanges on each side of the MX2800 STS-1at one of the three available positions.

Be sure to install the flanges with the screws provided.

3.After the flanges have been installed, position the MX2800 STS-1at the correct location within the rack and secure the mounting flanges to the mounting rails of the rack.

4.Make all network, DTE, and power connections to the rear of the unit. See Power Up on page 2-2 for more information on making the DC power connection.

5.Using the 8-positionmodular toDB-9female connector and the8-positionmodular to8-positionmodular cable, connect a

VT 100 terminal device to the CRAFT port on the front panel of the unit.

Two MX2800 STS-1smay be stacked with no spacing between units. ADTRAN recommends 1U (1.75") of separation above and below the two stacked units. This spacing allows the unit to dissipate heat. The design of the MX2800STS-1uses the chassis to distribute heat generated by the unit's internal cards. This design allows the unit to operate without a cooling fan, which increases its overall reliability.

61200659L1-1

MX2800 User Manual

2-5

Chapter 2. Installation and Operation

Connecting the Breakout Panel

The optional breakout panel (P/N 1200291L1) connects to the MX2800 STS-1via theIN andOUT Champ connectors located on the back of the unit, and provides 28 RJ connectors for the individual T1s/E1s. Shipment includes twosix-foot,64-pinto64-pinAmp cables which allow direct cabling to the

MX2800 STS-1.Connect the breakout panel’sIN Champ connector to the MX2800STS-1’sIN Champ connector and the breakout panel’sOUT Champ connector to the MX2800STS-1’sOUT Champ connector (seeFigure 2-2).

Front View

2

4

6

8

10

12

14

16

18

20

22

24

26

28

1

3

5

7

9

11

13

15

17

19

21

23

25

27

A

N

A

P

C

E

L

R

T

T

M

F

Rear View

IN

OUT

 

Cable 2

NET

115VAC 50/60HZ

0.8a

 

 

 

 

DSX-1/E1

DC POWER

 

L

NONCRITICAL

A

 

 

 

 

 

(OUT)

 

 

A

 

 

 

 

 

N

 

 

 

 

 

 

 

OUT

IN

 

PWR RET

PWR

RET

 

Cable 1

FAIL

FAIL

M

NO COM NC

 

B

 

A

CRITICAL

 

 

 

 

M

 

 

 

DSX-1/E1

 

 

O

 

B

 

 

USE COPPER

E

 

 

 

(IN)

 

CONDUCTORS ONLY!

D

 

 

 

 

 

Figure 2-2.The Breakout Panel

2-6

MX2800 User Manual

61200659L1-1

Chapter 2. Installation and Operation

REAR PANEL

The MX2800 STS-1rear panel is equipped with a LAN port, a modem port, two alarm output terminal blocks, two sets of NET in/out jacks, two Amphenol (Amp) connectors, and DC/AC power connections.Figure 2-3 illustrates the rear panel and identifies its equipment. Descriptions for these items follow the figure. Pin assignments are given inAppendix A, Pinouts.

L A N

M O D E M

 

3

NET

 

 

 

 

 

 

115VAC 50/60HZ

 

 

 

 

 

DC POWER

 

0.8a

1

 

 

 

 

 

 

 

NONCRITICAL

 

A

DSX-1/E1

 

 

 

 

7

 

 

(OUT)

 

 

 

 

 

OUT

IN

4

5

PWR

RET

PWR

RET

8

 

 

FAIL

 

NO COM NC

 

FAIL B

A

2

 

 

B

DSX-1/E1

 

 

6

 

USE COPPER

 

 

(IN)

 

 

 

CONDUCTORS ONLY!

 

 

 

 

 

 

 

 

CRITICAL

 

 

 

 

 

 

 

 

#

 

 

 

Item

Function

 

 

 

 

 

 

1

LAN

10BaseT LAN connection

 

 

 

 

 

Note: The LED to the right of this connector illuminates

 

 

 

 

 

when the unit is connected to an active ethernet seg-

 

 

 

 

 

ment.

 

 

 

 

 

 

2

Modem

Telephone line connection for internal V.34 modem (see

 

 

 

 

 

note on page 2-8)

 

 

 

 

 

 

3

Noncritical/Critical

Connections for external audible/visible alarms

 

 

 

 

 

 

4

NET

Network service connections for controller cards A and B

 

 

 

 

 

 

5

DSX-1/E1

64-pinAmp connectors for T1/E1s

 

 

 

 

 

 

6

Power

DC power connection

 

 

 

 

 

 

7

 

 

 

 

Ground stud

 

 

 

 

 

 

 

 

 

 

8

115 VAC 50/60Hz

AC power connection

 

 

 

 

 

 

Figure 2-3.MX2800STS-1Rear View

61200659L1-1

MX2800 User Manual

2-7

Chapter 2. Installation and Operation

LAN Port

The LAN port is an8-pinmodular connector that provides a 10BaseT ethernet LAN interface. ThisLAN interface is used for SNMP and Telnet control.

Connect the LAN port to intra-buildingwiring only.

Modem Port

The MODEM port is an8-pinmodular jack that provides a telephone line (POTS) connection for the internal V.34 modem.

The MX2800 STS-1can be configured as adial-inhost and also as adial-out-on-Trapdevice (meaning the unit dials out to a specified host to report error conditions).

Information regarding the built-inmodem applies to the following list of numbers: 4200659L1, L2, L3, and L4.

Noncritical and Critical Alarm Connectors

The alarm connectors connect to the three contacts of a Form C type relay on the main board of the MX2800 STS-1.This relay is activated any time the MX2800STS-1detects an alarm condition on theSTS-1network interface. BothNC (normally closed) andNO (normally open) contacts are provided.

Connect alarms to one of the three-positionmodular terminal lug connectors (provided). These connectors make it easier to perform initial wiring and to connect and disconnect alarms when replacing

2-8

MX2800 User Manual

61200659L1-1

Chapter 2. Installation and Operation

rackmount units. Once a modular connector is wired, push it firmly into the rear panel NONCRITICAL orCRITICAL connector.

The alarm functions can be enabled or disabled through the ALARM RELAYS section of theCONFIGURATION menu (see the sectionAlarm Relays on page 3-18).

Network Interfaces

The network interfaces are full-duplexcircuits provided by four BNC coaxial cable connections (two for each controller card). The receive data from the network is connected to the RX (IN) connectors, while the transmit data from the MX2800STS-1is connected to the TX (OUT) connectors.

Network interfaces must be connected using coaxial cables that have the shields grounded at both ends.

DSX-1/E1Interfaces

The DSX-1/E1interfaces are64-pinAmp connectors. These interfaces provide Tx and Rx connections between the unit and equipment such aswire-wrappatch panels,punch-downpanels, or breakout panels.

Connect the DSX-1/E1interfaces tointra-buildingwiring only.

Power Connection

The DC and AC power connections are described earlier in this chapter on page 2-2.

61200659L1-1

MX2800 User Manual

2-9

Chapter 2. Installation and Operation

FRONT PANEL

The MX2800 STS-1faceplate is shown below inFigure 2-4.

Descriptions of each part of the front panel follow.

A

N

A

P

C

E

L

R

T

T

M

F

Figure 2-4.MX2800STS-1Front Panel

Craft Port

The CRAFT port, an8-pinmodular jack, provides connection to aVT-100EIA-232compatible interface using the supplied8-pinmodular toDB-9female connector and the8-pinto8-pinmodular cable.

Establishing Terminal Connection

To connect the MX2800 STS-1to aVT-100terminal, follow the steps below:

1.Configure the VT-100terminal for 9600, 19200, 38400, or 57600 baud,8-bitcharacters, no parity, and one stop bit (xxxx, 8N1).

2.Using the terminal interface cable adapter provided by ADTRAN, connect the DTE port of a terminal to the 8-pinmodular jack labeledCRAFT on the MX2800STS-1front panel.

3.Initialize the terminal session.

4.Press Enter repeatedly until the password prompt appears.

5.Enter the password. The factory default password is adtran (alllower-case).TheMAIN MENU appears (seeFigure 2-5 on page 2-11).