Section 61109403L2-5

Issue 3, November 1997

CLEI Code: D4F1DFJ_ _ _

C A U T I O N !

PRACTICES

SUBJECT TO ELECTROSTATIC DAMAGE

 

OR DECREASE IN RELIABILITY.

 

HANDLING PRECAUTIONS REQUIRED.

2FXS/DPO PM

FOREIGN EXCHANGE STATION/DIAL PULSE ORIGINATE DATAPORT

WITH PERFORMANCE MONITORING

INSTALLATION AND MAINTENANCE

 

 

CONTENTS

 

1.

GENERAL ...................................................................

1

2.

INSTALLATION ...........................................................

2

3.

CONNECTIONS ..........................................................

4

4.

TESTING .....................................................................

4

5.

MAINTENANCE ..........................................................

5

6.

WARRANTY AND CUSTOMER SERVICE ................

5

 

 

FIGURES

 

Figure 1. 2FXS/DPO ...........................................................

1

Figure 2.

Circuit Path ..........................................................

3

Figure 3.

Connector ............................................................

4

 

 

TABLES

 

Table A. SW1 (Receive) and SW2 (Transmit) ...................

2

Table B. SW3, SW4, and SW5 Option Settings ................

2

Table C. Manual Configuration Guide ................................

3

Table D. Electronic Provisioning Settings ..........................

3

Table E. 2FXS/DPO Faceplate Indicators .........................

4

1. GENERAL

This practice provides installation and maintenance information for the ADTRAN® Intelligent2-WireForeign Exchange Station/Dial Pulse Originate (2FXS/DPO PM) Dataport with Performance Monitoring, part number 1109403L2. It is a D4 compatible channel unit and operates in any standard D4 channel bank. Intelligent features requires the unit to be used in the ADTRAN ACT 2300, ACT 1900 , or standard WECO® D4 channel bank using the ADTRANLIU-3/PMcommon unit. The 2FXS/ DPO PM provides an interface between a D4 channel bank Pulse Code Modulation (PCM) backplane interface and a2-wirevoice frequency (VF) transmission and signaling facility.Figure 1 is an illustration of the 2FXS/ DPO PM. The unit is multifunctional and can be provisioned to operate in the following modes:

2-WireForeign Exchange Station (2FXS)

Dial Pulse Originate (DPO)

Tandem FXS Mode

Private Line Auto Ringdown (PLAR)

SW 4 SW 3

SW 2

SW 1

SW 7

2FXS/DPO 1109403L2PM

AP

REM

PM

TEST

BUSY

Figure 1. 2FXS/DPO

Using the FXS/DPO PM in an intelligent channel bank provides additional features and functions such as:

Local and Remote Provisioning using either the craft interface or ADTRAN Site Manager through a menu driven program called EASYMENU™

Performance monitoring of the loop

Network and customer side monitoring and analysis

Enhanced Test Capabilities

Revision History

Revisions to this practice include CLEI code and dip switch settings.

Features

Backplane interface to the Pulse Code Modulation (PCM) bus.

On board coder/decoder (CODEC) uses μ-lawencoding/decoding.

Nominal 600 ohm or 900 ohm 2-WireVF interface with DC isolation.

61109.403L2-5C Trademarks: Any brand names and productSectionnames61109included.403L2in this-document5, Issueare3trademarks, registered trademarks, or trade names1 of their respective holders.

Tandem or private line automatic ringdown mode with D3 or D4 signaling.

Transmit and receive gain/attenuation adjustable in 0.1 dB increments.

Transmit input range of -4.5to 1.8 dBm.

Receive output range of -6.3to 0.0 dBm.

Complies with AT&T Publications 43801, 41008, 41009, and Bellcore GR-1089-CORErequirements for Type 1 Equipment.

Supports Calling Number Delivery and other common (CLASSTM) service offerings according to TR TSY 000030 section 3.3.1.1.

2. INSTALLATION

After unpacking the unit, immediately inspect it for possible shipping damage. If damage is discovered, file a claim immediately with the carrier and then contact ADTRAN customer service (see section 6, Warranty and Customer Service).

The 2FXS/DPO PM plugs directly into an ADTRAN ACT 2300/1900 or standard D4 channel bank. No installation wiring is required. To install, grasp the 2FXS/DPO PM by the faceplate and insert it into the backplane connector until firmly seated.

Provisioning Options

Most options on the 2FXS/DPO are provisionable either manually, using internal slide switches, or electronically using a menu-drivenprogram called EASYMENU. The trunk processing options are found on internal slide Switch 7 (SW7) and can only be provisioned manually.

Manualprovisioningshouldbecompletedbefore the 2FXS/DPO is inserted into the channel bank. Electronic provisioning should be completed following installation.

Manual Provisioning

Internal slide switches SW1,2, 3, 4, and SW7 are used to manually provision and set the operational modes and options of the unit. Figure 1 displays switch locations.

Slide switches SW1 and SW2 are used to set, receive, and transmitattenuation. TableA displaystheavailableoptions.

Slide switches SW3-1,2, 3, 4, andSW3-5are used to provision the desired operation mode of the unit.

Slide switch SW4 is used to provision the trunk processing (SD), dial pulse correction (DPC), loop or ground start (GS), PLAR mode (PD3), tandem battery mode (TRB), tandem start mode (TWS), dial tone (DTG), and ringback tone (RTG).

Slide switch SW7 is used to provision the trunk processing options: make busy lead (1G), make busy closure (L), and busy trunk sleeve (S). Table B summarizes the option settings for SW3, SW4, and SW7.

Table A. SW1 (Receive) and SW2 (Transmit)

Attenuation Options.

Function

Selection/Setting

 

 

Amount in dB

Activate

Add Attenuation

Switch to

 

 

 

"On" Position

 

 

0.1 dB

SW1,2 - 6

 

 

 

 

 

 

0.2 dB

SW1,2 - 5

 

 

 

 

 

 

0.4 dB

SW1,2 - 4

 

 

 

 

 

 

0.8 dB

SW1,2 - 3

 

 

 

 

 

 

1.6 dB

SW1,2 - 2

 

 

 

 

 

 

3.2 dB

SW1,2 - 1

Note 1:

Factory default setting for all switches is "off."

Note 2:

Multiple switch activation causes a cumulative effect

 

on the amount of attenuation added.

 

Note 3:

The largest transmit attenuation value in 2-Wire

 

mode is 6.3 dB.

 

 

 

 

 

Table B. SW3, SW4, and SW5 Option Settings

Function

Switch

Selection

Setting

 

 

 

 

 

Operational Mode

 

Impedance

SW3-1

900 ohms

ON

 

(Z900)

600 ohms

OFF

TNDM Mode

SW3-2

Enabled

On

 

(TNDM)

Disabled

Off

PLAR Mode

SW3-3

Enabled

On

 

(PLAR)

Disabled

Off

FXS Mode

SW3-4

Enabled

On

 

(FXS)

Disabled

Off

DPO Mode

SW3-5

Enabled

On

 

(DPO)

Disabled

Off

 

General Parameters

 

Ringback Tone

SW4-1

Enabled

On

 

(RTG)

Disabled

Off

Dial Tone

SW4-2

Enabled

On

 

(DTG)

Disabled

Off

Tandem Mode

SW4-3

Wink

On

Signaling

(TWS)

Immediate

Off

Tandem Mode

SW4-4

Reverse

On

Battery

(TRB)

Normal

Off

PLAR Mode

SW4-5

D3

On

Trunk Type

(PD3)

D4

Off

Start Mode

SW4-6

Group

On

 

(GS)

Loop

Off

Dial Pulse

SW4-7

Enabled

On

Correction

(DPC)

Disabled

Off

Busy Trunk

SW4-8

Enabled

On

During CFA

(SD)

Disabled

Off

 

Trunk Processing

 

Make Busy

SW7-2

Enabled

On

Lead 1 Ground

(1G)

Disabled

Off

Make Busy

SW7-3

Enabled

On

Closure

(L)

Disabled

Off

Busy Trunk Sleeve

SW7-4

Enabled

On

Option during CFA

(S)

Disabled

Off

 

 

 

 

2

 

Section 61109403L2-5,Issue 3

61109.403L2-5C

The trunk processing options are provisioned only by switch SW7. Electronic provisioning is not available.

Table C provides a guide to ensure proper provisioning of the desired channel unit mode.

Table C. Manual Configuration Guide

 

FXS

FXS

TANDEM

TANDEM

 

 

Options

Loop

Gnd

Loop

Gnd

PLAR

DPO

 

Start

Start

Start

Start

 

 

RTG

X

X

On/Off

On/Off

On

X

(SW4-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

DTG

X

X

On/Off

On/Off

X

X

(SW4-2)

 

 

 

 

 

 

 

 

 

 

 

 

 

TWS

X

X

On/Off

On/Off

X

X

(SW4-3)

 

 

 

 

 

 

 

 

 

 

 

 

 

TRB

X

X

On/Off

On/Off

X

X

(SW4-4)

 

 

 

 

 

 

 

 

 

 

 

 

 

PD3

X

X

X

X

On/Off

X

(SW4-5)

 

 

 

 

 

 

 

 

 

 

 

 

 

GS

Off

On

Off

On

X

X

(SW4-6)

 

 

 

 

 

 

 

 

 

 

 

 

 

DPC

On/Off

On/Off

X

X

X

X

(SW4-7)

 

 

 

 

 

 

 

 

 

 

 

 

 

SD

On/Off

On/Off

On/Off

On/Off

On/Off

On/Off

(SW4-8)

 

 

 

 

 

 

 

 

 

 

 

 

 

TNDM

Off

Off

On

On

Off

Off

(SW3-2)

 

 

 

 

 

 

 

 

 

 

 

 

 

PLAR

Off

Off

Off

Off

On

Off

(SW3-3)

 

 

 

 

 

 

 

 

 

 

 

 

 

FXS

On

On

Off

Off

Off

Off

(SW3-4)

 

 

 

 

 

 

 

 

 

 

 

 

 

DPO

Off

Off

Off

Off

Off

On

(SW3-5)

 

 

 

 

 

 

Note: X = Switch position is ignored.

Electronic Provisioning

ADTRAN EASYMENU is used to electronically provision the unit. Connect a VT 100 terminal or a computer running a terminal emulation program to the faceplate ADMIN port or REMOTE port using a standard male-to-maleRS-232cable. The settings for the ADMIN and REMOTE ports are shown inTable D.

A null modem cable is required to connect the REMOTE port directly to a terminal.

Table D. Electronic Provisioning Settings

 

ADMIN Port

REMOTE Port

Settings

9600 baud

SW2 baud

 

No Parity

No Parity

 

8 bits

8 bits

 

1 stop bit

1 stop bit

Once connected, enter the password. The factory default password is PASSWORD in all capital letters. The password may be changed by selecting:

Common Module Menus

(2)

BCU

(1)

Configuration

(1)

Read/Write Password

(9)

Before provisioning the unit electronically, access the channel unit by selecting:

Channel Unit Menus

(3)

Desired slot

(1-24)

Provisioning

(2)

Select current operational mode

(1-4)

Select desired provisioning option

(1-*)

For additional information on EASYMENU operation or the ADTRAN Site Manager, refer to the EASYMENU User Manual, document number 61150.055L1-1(found in the ACT 2300/1900 System Manual, document number2150.050-3),or the Site Manager User Manual, document number64150.075L1-1.For additional information about theLIU-3/PMsee theLIU-3/PMUser Manual, part number61151.001L2-1.

Initial Turn-up

Refer to the desired operational mode in Table C for the correct provisioning options.

Transmit Attenuation

Determine the input TLP. Then use the following formula to calculate the amount of transmit attenuation to add to the circuit:

Tx Attenuation=Input TLP + Internal Tx TLP of 4.5 dBm

For example, if an input TLP level of -3dB is to produce a level of 0dBm0 at TLP0, then the Transmit Attenuation should be set to 1.5 dB.

Receive Attenuation

Determine the output TLP. Then use the following formula to calculate the amount of receive attenuation to add to the circuit:

Rx Attenuation=Internal Rx TLP of 0 dBm) - Output

TLP

For example, if 0dBm0 at TLP0 is required to produce an Output TLP level of -3dB, then the Receive Attenuation should be set to 3 dB.Figure 2 provides an illustration of attenuation settings.

 

Transmit Path

 

 

Tx Atten

 

 

T

TDATA

 

 

-4.5to +1.8 dB

 

0 dBm0

Input TLP

0- 6.3 dB

TLPO

 

 

Rx Atten

 

0 to -6.3dB

 

RNPCM

Output TLP

R

0 dBm0

 

0- 6.3 dB

TLPO

 

Receive Path

 

Figure 2. Circuit Path

61109.403L2-5C

Section 61109.403L2-5,Issue 3

 

3

3. CONNECTIONS

The 2FXS/DPO PM occupies one card position in the D4 channel bank. The connector pin assignments are detailed in Figure 3.

4. TESTING

The 2FXS/DPO performs a self test after power on. During this time all four indicators turn On in a predefined sequence while the 2FXS/DPO verifies proper operation of critical circuits in the design. After successful completion of the self test, all indicators function in their normal mode.

Digital Loopback Test

The Digital Loopback Test is used to test loopback data coming from the network. Received data, or RNPCM, is latched in during the appropriate receive time slot. This data is then placed on the TDATA bus during the unit's transmit time slot.

 

28

1

FRM GND

 

29

2

-12V

+5V

30

3

12V GND

 

31

4

+12V

 

32

5

5V GND

 

33

6

TWD

 

34

7

TSP

TDATA

35

8

TSQ

 

36

9

RNPCM

RFB

37

10

RFA

RCLK

38

11

TDCLK

RWD

39

12

 

RSQ

40

13

RSP

 

41

14

RNDIS

 

42

15

-48FRT

-48F

43

16

 

 

44

17

-48SPRT

 

45

18

 

 

46

19

 

 

47

20

 

 

48

21

TFCC

IN

49

22

 

-48SD

50

23

2N

R

51

24

T

 

52

25

 

BT

53

26

RT

20HZ

54

27

RG

Figure 3. Connector

Pin Assignments

Network On-hook/Off-hookTest

The Network On-hook/Off-hooktest is used to test signaling sent to the network by the unit. WhenOn-hookTest is selected,On-hooksignaling is sent to the network. WhenOff-hookTest is selected,Off-hooksignaling is sent to the Network. The customer loop is forced Onhook while this test is active.

Customer Ringing Test

The Customer Ringing Test will activate the unit's ring relay in a 2-on/4-offring cadence, providing ringing to the customer loop when a ring generator is properly connected to the channel bank.

1004 Hz DRS Tone Generation Test

The 1004 Hz DRS (Digital Reference Signal) Tone Generation test is used to send the DRS signal to the network, loop, or both. When Network is selected, the DRS is sent to the network from the unit. The far end unit should measure a 1004 Hz tone at a level determined by the circuit gain of the far end unit. When Loop is selected, the DRS is placed on the receive path. The loop receive level is determined by the following equation:

Receive Level = 0dB - Attenuation

When the option BOTH is selected, tone is placed on both the loop and the network.

Accessing Tests Through EASYMENU

Once the unit is in normal operation, these test features are accessed by selecting:

Channel Unit Menus

(3)

Desired slot

(1-24)

Test

(4)

These tests are service affecting.

Faceplate Indicators

The 2FXS/DPO faceplate indicators and descriptions are explained in Table F.

Table E. 2FXS/DPO Faceplate Indicators

 

 

 

 

 

 

Indicator

Indication

Description

 

 

2FXS/DPO

 

 

 

 

 

 

1109403L2

REM

Off

Unit is manually provisioned.

 

 

 

 

PM

 

Green

Unit is remotely provisioned.

 

 

 

 

 

 

 

 

 

 

 

AP

 

Flashing

Configuration/provisioning error.

 

 

 

REM

PM

Off

PM mode is not operating.

 

 

 

 

 

 

 

PM

 

 

 

 

 

Green

PM mode is operating.

 

 

TEST

 

 

 

 

 

 

 

 

BUSY

TEST

Off

All tests are inactive.

 

 

 

 

 

 

 

Yellow

Test is active.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSY

Off

Network and Loop On-hook.

 

 

 

 

 

 

 

Green

Network, Loop, or both are Off-

 

 

 

 

 

 

 

 

hook.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

Selection

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alternate provisioning switch.

 

 

 

 

 

 

AP

Depressed

Changes provisioning source

 

 

 

 

 

 

from manual to remote or remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The 2FXS/DPO PM has four faceplate indicators and a depressed provisioning switch. The front panel PM (Performance Monitoring) indicator Flashes during control link establishment and remainsON after the channel unit has been remotely provisioned.

If the channel unit has been remotely provisioned, the operator can alternate between the remote configuration data stored in nonvolatile memory or manual switch settings by pressing the momentary AP (Alternate Provisioning) switch located on the front panel.

The REM indicator remains ON when the channel unit is operating based on Remote Provisioning, and isOFF when based on manual switches. If the channel unit has never been remotely provisioned, the AP switch has no effect and the REM indicator remainsOFF . The REM LEDFlashes when an invalid operation mode is selected.

4

 

Section 61109403L2-5,Issue 3

61109.403L2-5C