ADTRAN 1184519L1 User Manual

Size:
205.8 Kb
Download

CLEI: VAUIAMAP _ _

Product P/N: 1442140G1

Small Form-FactorPluggable Gigabit Ethernet,Single-Fiber40 km

Issue Date: 0804

Document P/N: 61442140G1-22A

DESCRIPTION

INSTALLATION

The Small Form-FactorPluggable (SFP) Gigabit Ethernet,Single-Fiberis a bidirectional SFP that plugs into the Central Office Optical Loop Termination (OLT) designed to accept SFPs. The SFP provides a single optical interface to the GigE physical interface. Installed into an appropriate OLT, the SFP provides a Gigabit Ethernet tributary interface to the supporting system.

NOTE: To ensure compatibility, refer to the documentation provided with the OLT.

The following features are supported on the SFP:

1000Base-LX1490 nm Transmitter

1000Base-LX1310 nm Receiver

Optical distance: 40 km maximum

CAUTION: Due to compliance certification requirements, only SFPs supplied by ADTRAN should be used. ADTRAN cannot certify system integrity with other SFPs.

Operational Specifications

Optical Specifications:

Optical transmit level: –2dBm to +3 dBm

Optical receive level: –23dBm to–3dBm

Optical connectors: LC

Extended Environmental Support:

Operational temperature range: –40°Cto +70°C

Storage temperature range: –40°Cto +85°C

Relative humidity to 95%, noncondensing

To install the SFP into an appropriate module, complete the following steps:

1.Inspect the SFP. If damaged, file a claim with the carrier and then contact ADTRAN Customer Service.

2.Do not remove the protective end cap from the SFP until the fiber optic cable is ready to be connected.

3.Insert the SFP into the SFP receptacle on the OLT. Ensure the manufacturer’s label on the SFP is facing upward for correct installation.

4.Slide the SFP all the way into the receptacle until there is an audible “click”.

NOTE: The latch on the SFP is used to remove the SFP from the cage on the circuit card.

5.Continue the installation and turn-upof the OLT using the instructions in the Job Aid that accompanied that OLT. The Installation and Maintenance Practice (I&M) for the ONT is available online atwww.adtran.com.

CLEI: VAUIAMAP _ _

Product P/N: 1442140G1

Small Form-FactorPluggable Gigabit Ethernet,Single-Mode40 km

Issue Date: 0804

Document P/N: 61442140G1-22A

COMPLIANCE

CAUTION: Electrostatic Discharge (ESD) can damage electronic modules. When handling modules, wear an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

The SFP is NRTL Listed to the applicable UL standards. The SFP meets or exceeds all the applicable requirements of NEBS, Telcordia GR-63-CORE,andGR-1089-CORE.The SFP is intended for deployment in Central Office type facilities, EEEs, EECs, and locations where the NEC applies (for example, Customer Premises and is intended to be installed by trained service personnel). Install the SFP in an ADTRAN product located in a restricted access location.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

1.This device may not cause harmful interference

2.This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN could void the user's authority to operate this equipment.

NOTE: The Gigabit Ethernet port(s) are optical and therefore are not classified as any type of port as defined in Appendix B of GR-1089-COREIssue 4.

The SFP is designed to meet the following environmental classes:

ETSI EN 300 019-1-1“Classification of environmental conditions; Storage,” Class 1.2

ETSI EN 300 019-1-2“Classification of environmental conditions, Transportation,” Class 2.3

ETSI EN 300 019-1-3“Classification of environmental conditions, Stationary use at weatherprotected locations,” Class 3.3

The equipment is designed to function without degradation during exposure to all test severities per Class 3.3.

CAUTION: Per GR-1089-COREthe ADTRAN system that the SFP is being deployed in is designed and intended for installation as part of a Common Bonding Network (CBN). The ADTRAN system that the SFP is being deployed in is not designed nor intended for installation as part of an Isolated Bonding Network (IBN).

Per GR-1089-CORESection 9, the SFP does not have an internal DC connection between battery return and frame ground. The SFP can be installed in aDC-I(isolated) orDC-C(common) installation. For installations where other cards or the host system have internal connections between battery return and frame ground, the system would be intended for deployment only in aDC-Cinstallation.

The ADTRAN system chassis frame ground terminal must be connected to an earth ground to ensure that the metal enclosure of the SFP is properly grounded via the backplane connector.

Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online atwww.adtran.com/warranty.

© 2008 ADTRAN, Inc. All Rights Reserved.

C A U T I O N !

PRICING AND AVAILABILITY

800.827.0807

TECHNICAL SUPPORT

800.726.8663

RETURN FOR REPAIR

256.963.8722

HANDLING PRECAUTIONS REQUIRED.

*61442140G1-22A*

SUBJECT TO ELECTROSTATIC DAMAGE

 

OR DECREASE IN RELIABILITY.