TOTAL ACCESS 750 QUAD FXS/FXO

JOBAID

61175408L2-22B

0006

QUAD FXS

L1 CLEI: SIC2WXOK_ _

L2 CLEI: SIC2WXHK_ _

QUAD FXO

L1 CLEI: SIC2VXOK_ _

L2 CLEI: SIC2VXHK_ _

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

TURN UP STEPS

1Insert card into slots1-6on the TA 750. The unit will automatically map DS0s in the T1 as noted below.

TIME SLOT ASSIGNMENT

Physical Slot

T1 Time Slot Assigned

1

1-4

2

5-8

3

9-12

4

13-16

5

17-20

6

21-24

2 Verify LED sequencing. LEDs will stop sequencing once unit is initialized.

Note: If the unit is inserted into a physical slot which has its timeslots allocated to the FT1(DSX-1)or Nx56/64 port, the LEDs will sequence continually, indicating a problem. The time slots must be freed up using the menu interface before the unit will become operational.

STATUS LEDS (GREEN)

OFF

On Hook

FLASHING

Ringing (FXS only)

ON

Off Hook (Busy)

SEQUENCING

All Four Time Slots Unavailable

 

 

 

3If factory default settings to be used for the application, then installation is complete. If further provisioning is desired proceed to step 4.

FACTORY DEFAULT SETTINGS

The FXS unit has factory default provisioning: FXS mode, loop start signaling and automatic loop provisioning. The automatic loop provisioning function will automatically set the line impedance and gain after the first off hook event.

The FXO factory default settings are FXO mode and loop start signaling.

If different settings are desired, the VT 100 terminal interface is used.

4Connect VT 100 compatible terminal to BCU faceplate ADMIN port4a ConnectDB-9cable

4b Run terminal emulation program

Craft Port Settings are as follows: 9600 Baud, No parity, 8 data bits, 1 Stop bit, No flow control.

4c If using Windows Hyperteminal open by selecting

Programs/Accessories/Hyperterminal

Note: To ensure proper display background, selectVT 100 Terminal Emulation underSettings.

5Proceed through menus to desired access module

5a select Access Modules

5b select1-6 (slot)

5c select1-4 (circuit)

Note: To traverse through the menus, select the desired entry and press Enter. To work backwards in the menu pressESC (escape key). To return to the top of the menu at any time, press the return key twice.

6Change port provisioning for a particular application.

Note: Provisioning for a port can be copied to another port or to all similar ports.

7Testing - to access the test menu for an access module selecttest (item 4 after 5c)

TESTING

Self Test

Performed when the Quad FXS or FX0 is inserted into an active chassis to verify proper operation of critical circuits.

Initiated Tests

Digital Loopback Test – loops back DS0 data coming from the network for each individual channel.

Network On-Hook /Off-HookTest – tests signaling sent to the network by the unit.

Customer Ring Test (FXS only) – activates the unit’s ring relay in a2-on /4-offring cadence, providing ringing to the customer loop.

1000 Hz DRS Tone Generation Test – sends DRS signal on the receive path to the loop and transmit path towards Carrier.

Note: All tests except self test are initiated through the TA 750 BCU Admin Port, TA 850 RCU, or TA 1500 SCU.

Note: The Quad FXS is for use in the TA 750 and the TA 850.

The Quad FX0 is for use in the TA 750, the TA 850, and the TA 1500.

Note: The 1175408L2 is completely interchangeable with the 1175408L1. The 1175407L2 is completely interchangeable with the 1175407L1.

For a complete Quad FXS I&M Practice: 877.457.5007, Document # 484. Please have your fax number available.

For a complete Quad FX0 I&M Practice: 877.457.5007, Document # 485. Please have your fax number available.

TOTAL ACCESS 750 QUAD FXS/FXO

PRICING AND AVAILABILTY

800.827.0807

TECHNICAL SUPPORT 888-4ADTRAN

RETURN FOR REPAIR

256.963.8722

www.adtran.com

CONNECTIONS

All connections are made through the50-pinamphenol connector on the back panel TA 750/850/1500.

ELECTRICAL CODE COMPLIANCE

MODES OF OPERATION

Note: Signaling states are provisioned through the BCU.

FXS

FXS Loop Start (default)

FXS Ground Start

The Quad FXS and Quad FXO are to be installed in restricted access locations and in equipment with a Type “B” or “E” installation code.

Code

Input

Output

IC

A

TC

X

PC

C

C

TR-08Single Party

TR-08Universal Voice Grade

DPO

Tandem (E & M)

FXO

FXO Loop Start (default)

FXO Ground Start

APPLICATIONS

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.

Switch

DPT

ATTENUATION LEVELS

0 dB to -9dB

FXS

Short loop default: -6dB Transmit,–3dB Receive

Long loop default: -3dB Transmit,–3dB Receive

FXO

Default 0 dB Transmit, 0 dB Receive

Switch

 

 

DS1

 

Data Switch

 

 

TDM

 

 

 

 

GR303

DS1

DCS

 

Router

 

 

 

Switch

GR303 Access

 

 

 

Concentrator

 

IMPEDANCE SETTINGS

FXS

600

900

600 + 2.16 µF (short loop default)

900 + 2.16 µF (long loop default)

FXO

900 + 2.16 µF

WARRANTY