ADC WorldDSL User Manual

0 (0)
ADC WorldDSL User Manual

Spec Sheet

WorldDSLG.S

Double Pair/Line Power

G.SHDSL for CO and Customer Premises

ADC’s WorldDSL G.S is a family of high-speed G.shdsl access devices complying with the ITU-T G.991.2 G.shdsl standard. These modems are specifically designed for the diverse

telecommunication needs of global markets. Ideal for telco and enterprise networks, WorldDSL G.S products conform to international standards to ensure compatibility, performance and safety within your network environment.

The new G.shdsl modems are part of the broad

family of WorldDSL HDSL modems and share common chassis’, enclosures, management software and accessories. They are fully G.shdsl compliant including 36/72 timeslot operation and all required performance monitoring statistics. Both G.821 and G.826 statistics are provided for E1 ports giving users maximum flexibility. Each WorldDSL G.S modem is software-selectable as a communication master or communication slave, so any two units can be used for a point-to-point circuit. The modems are part of a fully managed system, interfacing with a VT100 compatible terminal or a PC. The units can be managed via their local craft port or a central management card installed in a CO shelf. ADC’s Stargazer, Windows or UNIX-based SNMP management software can be used to provision the system, collect alarm and performance data, and conduct diagnostic tests locally or from a remote management station. In any of these modes, the remote unit can be programmed and managed through the CO, minimizing travel to the outdoor site.

Features:

Fiber optic quality (BER 10-10)

Single pair operation or double pair operation to double the bandwidth or extend the reach

Single Pair – 2.304 Mbps Double Pair – 4.608 Mbps

Nx64K rate selectable from 64 kbps to 2.304 Mbps single pair or 64 kbps to 4.608 Mbps double pair

E1 and FEI (Fractional EI)

10/100 Ethernet bridge

Automatic protection of TS0 and TS16 for fractional E1 use

Software programmable data port—V.35/V.36/RS- 530/X.21

E1/FE1 and dataport or E1/FE1 and Ethernet port simultaneous operation sharing the bandwidth

Intelligent multi-range line power management for 120, 150, and 200 VDC per EN60950

Complete G.shdsl reach/range coverage including line power

Support wetting current

One pair can be set up as 1+1 protection for the other pair, TSP

Two pairs can also be configured as point to multi-point

Auto loop crossover management

10/100 IEEE 802.3u, layer 2 MAC bridge, wirespeed, auto negotiation or programmable for 10/100, full/half modes

Centralized software download for easy upgrade

Jitter meets G.823 requirements

w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1

1 2 / 0 6 • 1 0 0 4 5 8 A E WorldDSLG.S

WorldDSLG.S

Specifications

SHDSL Interface

Line Code: 16 Level Trellis coded PAM Line Data Rate: user selectable from 1-pair 192 kbps to 2.304 Mbps 2-pair 384 kbps to 4.608 Mbps

Range: (see chart on next page) Connector: DB9F (adapters available) Protection: ITU-T K.20 and K.21 compliant Compliance: ITU-T G.991.2

E1 Interface

Line Code: HDB3

Data Rate: 64 kbps to 2048 kbps Operation: full or fractional Blocking: per 64 kbps channel

Idle Code Insertion: user selectable word Impedance: 120 Ω balanced or 75 Ω unbalanced

Framing: structured with or without CRC-4 or unstructured Connectors: both D15F (balanced) and BNC (unbalanced) Timing: internal, external, G.703

Compliance: ITU-T G.703, G.704, G.706, G.821, G.823, G.826, CTR12

10/100 Ethernet Interface

802.3U Mac bridge

Auto sensing 10/100 Half or full duplex VLAN pass through

Data Interface

User software selectable as: V.35, V.36, RS-530, X.21

Data Rate: 64 kbps to 2304 kbps or 64 to 4608 kbps (2 pair) Connector: D25F (adapters available)

Timing: internal, external, loop, Nx64 Compliance: Net 2

Performance Monitoring

DSL PM: ES, SES, UAS, CV, LOSW seconds

DSL Alarms: noise margin, loop attenuation, errored seconds, loss of synch word

DSL Alarms Thresholds (user settable): noise margin, loop attenuation, errored seconds E1: G.821 and G.826

Performance Measurements: ES, SES, UAS, BBES, ESR, SESR, BBER E1 Alarms: LOS, LFA, RAI, RAIS

PM History: 96x15 minute increments, 7x24 hour increments for both HDSL and E1 performance. Indefinite resettable alarm log showing first and last occurrence date and time, and number of occurrences for each alarm type

Alarm Relay: Form C relay contacts NO, NC and COM Loopbacks: local or remote towards customer or central office

Test pattern: PRBS generator and BER meter from the customer premise or CO ends

Power

Input Power: DC -36 to -72 VDC or AC 90 to 264VAC 47 to 63 Hz.

Line Power

Cover full reach for G.shdsl standard span. One pair, two pair, 120 VDC, 150 VDC, 200 VDC

Chassis/Enclosure

Chassis: EMS-830 or EMS-832; Enclosure: ERE-811 L5, L6 or L7 single-slot enclosure

Environmental

Operating Temperature: -5ºC to +50ºC; Storage Temperature: -40ºC to +85ºC Humidity: up to 95% RH non-condensing

Safety/Emissions Compliance

CE Marked

Safety: EN60950; Emissions, Susceptibility and Immunity: EN 300386-2. CO IN EMS-83x, Other Locations in ERE-811 or ETU versions