ADC ComProtect Building Entrance Terminals (BET) User Manual

Size:
122.21 Kb
Download

ComProtect® Building Entrance Terminals (BET)

Enclosed, Integrated Protection with LSA-PLUS® Series 2 Blocks

Spec Sheet

 

 

 

 

100 pair

50 pair

 

 

 

 

ADC's ComProtect Building Entrance Terminals provide high-densityprimary protection at commercial demarcations and are fully compliant to UL® and Telcordia® specifications. These units can be used in both indoor and outdoor applications and provide up to 50% space savings over traditional Building Entrance Terminals using5-pinprotection.

Features:

Telcordia approved ComProtect protection modules safeguard valuable cable plant and equipment from voltage surges and spikes

Lockable metal enclosure with Telco override cover and a splicing chamber with the choice of either 710 or MSsplice connectors

LSA-PLUScross connect field and protection field combined forHigh-DensitySolution

Lightweight, compact and removable top to enable stacking units

Instructions, template and mounting hardware included to mount the terminal directly to a wall

Reduced size over traditional BET footprint for tight to fit spaces

Applications:

Primary protection at commercial and MDU demarcation points

Primary protection for campus environments

Compliances:

UL® 497 listed

100% compliant with Telcordia GR-937

MSis a registered trademark of 3M.

UL® is a registered trademark of Underwriters Laboratories. Telcordia® is a registered trademark of Telcordia Technologies, Inc.

w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1

8 / 0 8 • 1 0 6 7 1 2 A E   ComProtect® Building Entrance Terminals

ComProtect® Building Entrance Terminals (BET)

Enclosed, Integrated Protection with LSA-PLUS® Series 2 Blocks

Specifications

ELECTRICAL CHARACTERISTICS:

 

 

 

BET Dielectric Withstand

 

4000 VDC

CONSTRUCTION CHARACTERISTICS:

 

 

 

 

 

 

 

 

 

Dimensions:

 

 

 

 

25-pairand

 

252.22mm x 314.96mm x 165.10mm

 

Indoor/Outdoor

50-pair

 

9.93"H x 12.40"W x 6.50"D

 

 

 

 

 

 

100-pair

 

377.19mm x 314.96mm x 161.10mm

 

 

 

 

 

 

14.85"H x 12.40"W x 6.50"D

 

 

 

 

 

 

 

 

 

 

 

MECHANICAL CHARACTERISTICS:

 

 

 

LSA-PLUSSeries 2 Subscriber Interface:

 

 

 

Contact Resistance

 

< 1 m Ω

Insulation Resistance

 

≥ 5 x 104

Contact Material

 

Copper Alloy

Contact Plating

 

Silver

Number of Test Cord Insertions

 

> 750

 

IDC Reterminations

 

200

 

Wire Diameter Range for Solid and Stranded Copper Conductors:

 

 

Two Conductors per Contact (same diameter)

22-26AWG

0.65 to 0.40 mm

 

 

 

 

(0.026" to 0.016")

One Conductor per Contact

20-26AWG

0.90 to 0.40 mm

 

 

 

 

(0.035" to 0.016")

Wire Insulation Diameter Range (PE,PVC)

 

0.68 mm to 1.60 mm

 

 

 

 

(0.027" to 0.063")

ENVIRONMENTAL CHARACTERISTICS:

Operating Temperature:

Indoor/Outdoor

-40˚ to 80 ˚ C(-40˚ to 176 ˚ F)

 

 

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

2

8 / 0 8 • 1 0 6 7 1 2 A E   ComProtect® Building Entrance Terminals

ComProtect® Building Entrance Terminals (BET)

Enclosed, Integrated Protection with LSA-PLUS® Series 2 Blocks

O r d e r i n g I n f o r m a t i o n

Description

 

Catalog Number

 

 

 

25-pairIndoor/Outdoor

 

 

Enclosed building entrance terminal

Quantity: 1

 

 

 

710 splice connector input

 

6649CP 2 720-00

 

 

 

MSsplice connector input

 

6649CP 2 760-00

50-pairIndoor/Outdoor

 

 

Enclosed building entrance terminal

Quantity: 1

 

 

 

710 splice connector input

 

6649CP 2 820-00

 

 

 

MSsplice connector input

 

6649CP 2 860-00

100-pairIndoor/Outdoor

 

 

Enclosed building entrance terminal

Quantity: 1

 

 

 

710 splice connector input

 

6649CP 2 920-00

 

 

 

MSsplice connector input

 

6649CP 2 960-00

ComProtect overvoltage protection modules sold seperately.

Other configurations available; please contact ADC Technical Assistance Center. MSis a registered trademark of 3M.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

3

Spec Sheet

Website: www.adc.com

From North America, Call Toll Free: 1-800-366-3891• Outside of North America:+1-952-938-8080Fax:+1-952-917-3237• For a listing of ADC’s global sales office locations, please refer to our website.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101

Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

106712AE  8/08  Revision  ©  2008  ADC Telecommunications, Inc.  All Rights Reserved