As mobile usage continues to increase, service providers are faced with the challenge of optimizing and expanding their wireless networks to provide new and existing services. ADC’s ClearGain® Tower-MountedAmplifiers (TMAs) minimize the cost of network expansion and improve the quality of service, allowing carriers to increase profitability from new and existing services.

ClearGain TMAs improve signal quality by boosting the uplink (RX) signal of a mobile system immediately after the antenna. This compensates for the loss in signal strength that occurs when the signal is passed through the coaxial feeder cable to the base transceiver station (BTS) at the base of the tower. These TMAs perform this amplification with the lowest possible noise contribution, resulting in a substantial increase in receiver performance and an improvement in overall coverage. These improvements in quality of service allow mobile subscribers to place more

calls, make longer calls, and successfully complete calls in an expanded geographic area, resulting in increased revenue.

Benefits:

Small size and low weight. Allows for easy installation with minimal visual impact and in weight-restrictedimplementations.

Improved uplink coverage. TMAs enable base stations to receive mobile signals more clearly in a wider coverage area than could otherwise be achieved.

Increased RF performance. By improving signal quality and/or reducing mobile phone power transmission, TMAs provide more successful call attempts, a reduction in dropped calls, maximized data rate, improved call quality and the extension of handset battery life.

Fully AISG compliant.

w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

ClearGain® Dual Inline TMAs

Americas

The ClearGain Dual Inline AWS TMA allows for mounting of the equipment to serve two RX paths in one location on the tower, reducing time and expense in mounting the TMA. The inline feature also allows for easier connection of the jumper cables to the antenna.

A ClearGain TMA system is modular, consisting of both a masthead unit (MHU) and a power distribution unit (PDU), providing full compatibility with all base stations. Due to its exposed installation, the TMA

is designed to withstand demanding weather conditions and features lightning protection, fault monitoring, and a fail-safebypass circuitry system.

towerMounted Amplifier

power Distribution Unit

Bias-t

+ -

NO cOM Nc

MhU

MhU1 MhU2 MhU3

INpUt

ALARM

DIScONNect

Base

Station

BtS

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

ClearGain® Dual Inline TMAs

Americas

AWS Dual Inline Typical Specifications

ELECTRICAL

 

Nominal Impedance of RF Inputs and Outputs:

50 Ohm

Frequency Range

 

TX:

2110 – 2155MHz

RX:

1710 – 1755MHz

Passband (RX)

 

Gain:

12db

Noise Figure:

1.4dB

Dynamic Range:

 

Input at 1 DB Gain Compression:

+13dBm

0utput IP3:

+25dBm

Bypass Insertion Loss:

2.0dB

Isolation in Tx Path:

>50dB

Insertion Loss of TX Path (TX to ANT):

0.5dB

Passband Return Loss

 

Tx Band:

18dB

Rx Band:

18dB

Rx Rejection in Tx Band:

>75dB

PHYSICAL

 

Dimensions (HxWxD):

210 mm x 166 mm x 81 mm

Weight:

4.5kg

Housing:

Aluminium

CONNECTORS

 

Antenna Connector:

7/16 DIN Female

BTS Connector:

7/16 DIN Female

ENVIRONMENTAL

 

Operating Temperature:

-40°Cto +60°C

Lightning Protection:

BTS Port 10kA 8/20us

 

ANT Port 10kA 8/20us

VIBRATION

 

Storage:

ETS3019-1-1

Transport:

ETS3019-1-2

Operation:

ETS3019-1-4Class 4.1E

REGULATORY

 

EMC:

ETS 300 342-3

APPROVALS

 

AISG:

AISG 1.1

CE:

Per IEC 61000 and IEC 60950

QUALITY

 

MTBF:

500,000 hours

ADC is an active member of the Antenna Interface Standard Group.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

ClearGain® Dual Inline TMAs

Americas

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

STRB-NF-NM-G-KIT

STRB-NM-NF-G-KIT

STRB-DM-DF-G-KIT

STRB-DF-DM-G-KIT

Bias-TUnits

ADC’s newly enhanced Bias-TUnits can be used indoors and outdoors in conjunction with the ClearGain power distribution unit (PDU). These versatile units, also known as DC current injectors, insert DC power into the coaxial cable and extract alarm and monitoring signals from the coaxial cable.

PRODUCT CONFIGURATION

 

Main path connectors:

Refer to ordering information for configurations

DC injection/Sample port connector:

TNC jack (female)

Mounting and grounding:

/M8 / brk (MH - bulkhead mounting/

 

M - screw / brk - bracket)

TECHNICAL DATA

 

Impedance:

50 ohms

Frequency range:

800 to 2200 MHz

Return loss:

> 19 dB

Insertion loss:

< 0.2 dB

RF CW power:

500 W

PIM 3rd order:

-108dBm

Surge current handling capability:

3kA single

Operating temperature:

-40°Cto + 65°C

Waterproof degree:

IP 65

DC injection / DC bypass current:

< 2 A

DC supply / DC bypass voltage:

< 48 V

MTBF:

600,000 hours

Size:

125 mm x 110 mm x 45 mm

 

(4.9 in x 4.3 in x 1.8 in)

Weight:

0.8 kg (1.8 lbs.)

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

 

ClearGain® Dual Inline TMAs

Americas

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

Dual Inline Power Distribution Unit

Time and space are important considerations when selecting and installing wireless components at base transceiver station sites. The simple, compact design of ADC’s ClearGain Power Distribution

Unit (PDU) is intended to help service providers save both. From a compact unit that is easily mounted on a wall or in a rack, the ClearGain PDU provides power and alarming for up to three ClearGain Tower-MountedAmplifiers.

Features:

Provides power and alarm functions for on-sitemonitoring of up to threedual-inlinemasthead units (MHUs)

Monitors condition of feeder cable

Wall or rack-mountableto fit available space

LED indicators for alarm functions

Simple, compact design allows for easy installation and connections

AISG compliant

The ClearGain Dual Inline TMA system is modular, consisting of an MHU and a PDU, providing full compatibility with all base stations.

The ClearGain Dual Inline PDU is an integrated unit that provides power and alarm functions for the ClearGain TMA system. The PDU monitors the current of the MHU. If an MHU fails, the ClearGain Dual Inline PDU gives an alarm indication. The ClearGain Dual Inline PDU also monitors the condition of the feeder cable. Alarm indicators identify failure in the feeder cable or MHUs and in which MHU the failure occurred, providing fast and easy on-sitediagnostics.

The flexible design of the ClearGain Dual Inline PDU allows it to be rack-mountedor mounted indoors on the wall or on the side of a BTS cabinet.

An external Bias-Tunit is used in conjunction with the Dual Inline PDU and is designed to connect directly into the BTS coaxial connector.Bias-Tunits are available with various connector types, with gas tube arrestors for lightning protection on the ANT and MHU ports. Quarter wave stub lightning protection is integrated on the BTS port of theBias-Tunits.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

ClearGain® Dual Inline TMAs

Americas

Dual Inline Power Distribution Unit Typical Specifications

Electrical

 

Input Voltage:

20-56Vdc positive/negative ground

Output Voltage:

3x16 Vdc each

Maximum Current Draw:

3A

Physical

 

Dimensions (HxWxD):

43 x 196 x 103 mm

Weight:

1 kg

Color:

Silver

Connectors

 

Output for MHUs:

SMB, male (qty 3)

Power Connector:

4-pinmale

General Alarm Connector:

3-pinmale

General Communications Connector:

3-pinmale

Indicators

Green OK/NOK LEDs

 

Red General Alarm LED

Alarm Output

Alarm output is isolated 3-pinrelay

 

connection. Normally open and

 

normally closed connection available.

Environment

 

Storage:

ETS3019-1-1

Transportation:

ETS3019-1-2

Operation:

ETS3019-1-3

Housing:

IP40

Temperature Range (Indoor Use):

-20°Cto +65°C

Lightning Protection:

IEC 1000-4-5EMC

Approvals

CE

Quality

MTBF 250,000

 

Manufactured under ISO 9001 quality system

Accessories

 

Basic Accessories:

Power supply cable (10 m), alarm cable (10 m),

 

communications cable (10 m), grounding cable (2 m)

 

and wall mounting screws

Optional Accessories:

Mounting hardware for 19” rack mount

 

ADC is an active member

 

of the Antenna Interface

 

Standard Group.

O r d e r i n g I n f o r m a t i o n

Description

Catalog Number

 

 

ClearGain Masthead Unit

CG0AWSDD155DT00

 

 

Bias-TKits*

 

 

 

7/16 DIN male to BTS, 7/16 DIN female to ANT

STRB-DM-DF-G-KIT

 

 

7/16 DIN female to BTS, 7/16 DIN male to ANT

STRB-DF-DM-G-KIT

 

 

N female to BTS, N male to ANT

STRB-NF-NM-G-KIT

 

 

N male to BTS, N female to ANT

STRB-NM-NF-G-KIT

 

 

Dual Inline Power Distribution Unit – Includes power cable and grounding cable

CG0000000000PFM

 

 

*Bias-T,DC Cable 4.25 meters (SMB to TNC), Grounding Cable 1.5 meters (one end terminated) Approved for use with ADC supplied Masthead Units only.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

8 / 0 7 • 1 0 5 1 8 8 A E ClearGain Dual Inline TMAs

ClearGain® Dual Inline TMAs

Americas

Creating a Bill of Materials

A typical site includes three components in various quantities.

You have one TMA option:

 

1. CG0AWSDDI55DT00

AWS Dual Inline TMA

The TMAs include: • Mounting hardware

• Grounding cable/strap (length 1.5 meters)

Ordering information: Order one per sector

You have four Bias-T options (based on connector type and orientation):

1. STRB-DF-DM-G-KIT

DIN Female to BTS Port, DIN Male

to ANT Port

2. STRB-DM-DF-G-KIT

DIN Male to BTS Port, DIN Female

to ANT Port

3. STRB-NF-NM-G-KIT

N Female to BTS Port, N Male

to ANT Port

4. STRB-NM-NF-G-KIT

N Male to BTS Port, N Female

to ANT Port

The Bias-Tsinclude:

• Grounding cable/strap (length 1.5 meters)

 

Bias-Tcable; go fromBias-Tto the PDU (length 14 feet)

Ordering information: Order one per sector

You have one PDU option:

1. CG0000000000PFM

Dual Inline PDU

The PDU includes:

Mounting Hardware

• Power Cable (length 10 meters)

• Alarm Cable (length 10 meters)

• Grounding Cable/strap (length 1.5 meters)

Ordering information: Order one per site

Optional Accessories:

Longer Bias-TCableCG-PDU-30CABLE(30 footBias-Tcable)

PDU Rack Mounting Brackets AUX-000076(19" rack mounting bracket)AUX-000076&EB-17P(23" mounting bracket)

AUX-000084(Siemens cabinet mounting bracket)

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

 

Spec Sheet

Website: www.adc.com

From North America, Call Toll Free: 1-800-366-3891• Outside of North America:+1-952-938-8080Fax:+1-952-917-3237• For a listing of ADC’s global sales office locations, please refer to our website.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101

Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

105188AE 8/07 Original © 2007 ADC Telecommunications, Inc. All Rights Reserved